{"title":"GAS DETECTORS","description":"Gas Detection devices that perform when it matters. Get single gas, 3 gas and 4 gas detectors from RKI Instruments, one of the world’s most leading manufacturers of gas detection instruments.","products":[{"product_id":"gx-3r-personal-gas-detector-rki-instruments","title":"GX-3R Personal Gas Detector by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GX-3R personal four-gas monitor for confined spaces: LEL, O2, H2S and CO, small enough to clip in the breathing zone.\u003c\/p\u003e\n\u003cp\u003eModel 72-RA-C: GX-3R for LEL \/ O2 \/ H2S \/ CO with Li-ion battery pack and 100–240 VAC charger.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact: 2.2 in W x 2.55 in H x 1.02 in D, 3.52 oz\u003c\/li\u003e\n\u003cli\u003eH2-compensated CO sensor available\u003c\/li\u003e\n\u003cli\u003eDual-filament LEL sensor for increased resistance to silicone poisoning\u003c\/li\u003e\n\u003cli\u003eElectrochemical O2 sensor with 3–5 year life; combo H2S\/CO micro sensor\u003c\/li\u003e\n\u003cli\u003eNon-compliance indicator: LEDs flash every 30 s (adjustable) if bump test or calibration is due or after a gas alarm\u003c\/li\u003e\n\u003cli\u003eAudible, visual and vibration alarms; 3 user-adjustable alarm levels; simple 2-button operation\u003c\/li\u003e\n\u003cli\u003e25 hours operation (Li-ion); IP66\/68; 3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 x 2.55 x 1.02 in; 3.52 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66\/68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 h (Li-ion)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications (manufacturer)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eGas Detected\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e (CO)\u003cbr\u003eH2 Compensated \u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide(CO)\u003c\/td\u003e\n\u003ctd\u003eHydrogen Sulfide(H2S)\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\"\u003eH2S\u003cbr\u003eOnly\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e Combustible Gases\u003cbr\u003e(Methane as standard) \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e Oxygen \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e Dual Sensor \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Slot\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e 1 \u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e 3 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Detection\u003cbr\u003ePrinciple \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDual EC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eEC\u003c\/td\u003e\n\u003ctd\u003e Catalytic combustion \u003c\/td\u003e\n\u003ctd\u003e EC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003cbr\u003e(Increments)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e 0 ~ 2,000 ppm\u003cbr\u003e(1 ppm) \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0 ~ 200.0 ppm\u003cbr\u003e(0.1 ppm)\u003c\/td\u003e\n\u003ctd\u003e 0 ~ 100% LEL\u003cbr\u003e(1% LEL) \u003c\/td\u003e\n\u003ctd\u003e 0 ~ 40% Vol. (0.1%) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003eStatement\u003c\/td\u003e\n\u003ctd\u003e ± 5% of reading\u003cbr\u003eor ± 2 ppm CO \u003c\/td\u003e\n\u003ctd\u003e± 5% of reading\u003cbr\u003eor ± 5 ppm CO\u003cbr\u003e(whichever is greater)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e± 5% of reading\u003cbr\u003eor ± 2 ppm H2S\u003cbr\u003e(whichever is greater)\u003c\/td\u003e\n\u003ctd\u003e ± 5% of reading\u003cbr\u003eor ± 2% LEL\u003cbr\u003e(whichever is greater) \u003c\/td\u003e\n\u003ctd\u003e ± 5% of reading O2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Method\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003e Diffusion sampling standard (hand aspirator or clip-on motorized pump optional) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003e Digital LCD displays with 7 segment plus 14 segment plus icon \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreset Alarms\u003cbr\u003e(User Adjustable)\u003cbr\u003eOverscale alarm\u003cbr\u003e(Non-adjustable)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1st alarm: 25.0 ppm\u003cbr\u003e2nd alarm: 50.0 ppm\u003cbr\u003e3rd alarm: 1200.0 ppm\u003cbr\u003eTWA alarm: 25.0 ppm\u003cbr\u003eSTEL alarm: 200.0 ppm\u003cbr\u003eOver alarm: 2000.0 ppm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1st alarm: 5.0 ppm\u003cbr\u003e2nd alarm: 30.0 ppm\u003cbr\u003e3rd alarm: 100.0 ppm\u003cbr\u003eTWA alarm: 1.0 ppm\u003cbr\u003eSTEL alarm: 5.0 ppm\u003cbr\u003eOver alarm: 200.0 ppm\u003c\/td\u003e\n\u003ctd\u003e1st alarm: 10% LEL\u003cbr\u003e2nd alarm: 25% LEL\u003cbr\u003e3rd alarm: 50% LEL\u003cbr\u003eOver alarm: 100% LEL\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypes of Alarms\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eGas Alarm: 3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing\/increasing.\u003cbr\u003eTrouble alarm: Sensor disconnection, low battery, circuit error, calibration range error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay of Alarm\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eGas Alarm: Flashing LEDs, continuous buzzer (100 db @ 30 cm), flashing gas value, vibration\u003cbr\u003eTrouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp.\u003cbr\u003e\u0026amp; Humidity\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003e-20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment)\u003cbr\u003e-40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eWithin 30 seconds (T90)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eLithium-ion battery, Approx. 25 hours after a 3 hour full charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eATEX, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension\u003cbr\u003e\u0026amp; Weight\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003e2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm), 3.52 ounces (approx. 100 g) without rubber booth\u003cbr\u003e2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm), 3.70 ounces (approx. 105 g) with rubber booth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eExplosion proof, dust and water resistant to IP-66\/68 (2m,1h) approval. Drop height 23 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eTwo buttons: POWER \/ MODE, AIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatalogging\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eLogs user ID, station ID, Calibration \u0026amp; Bump Test history, Alarm Events \u0026amp; Alarm Interval Trends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003cbr\u003eAccessories\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eAlligator clip, protective rubber boot, charger, and calibration adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003cbr\u003eAccessories\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eSDM-3R calibration station\u003cbr\u003eRP-3R Clip-on sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available)\u003cbr\u003ePadded carrying case for GX-3R and accessories\u003cbr\u003eUSB to IrDA downloading cable for datalogger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"11\"\u003eThree years material and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-RA-C\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39468099731491,"sku":"72-RA-C","price":1123.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/GX-3R-PERSONAL-GAS-DETECTOR-russmillsafety.com.png?v=1794189726"},{"product_id":"gx-3r-pro-gas-detector-with-wireless-communication-by-rki-instruments","title":"GX-3R Pro Gas Detector with Wireless Communication by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GX-3R Pro five-gas monitor with Bluetooth wireless communication: LEL, O2, CO, H2S plus a fifth channel for infrared or toxic sensors.\u003c\/p\u003e\n\u003cp\u003eModel 72-PAC-C: GX-3R Pro for LEL \/ O2 \/ combo H2S \u0026amp; CO \/ SO2 with Li-ion battery pack and 100–240 VAC charger.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact: 2.9 in W x 2.6 in H x 1.06 in D, 4.58 oz\u003c\/li\u003e\n\u003cli\u003eToxic options include HCN, NO2, PH3, SO2 and CO2; H2-compensated CO available\u003c\/li\u003e\n\u003cli\u003eTwo field-interchangeable sensor slots; field-replaceable sensors and filters\u003c\/li\u003e\n\u003cli\u003eBluetooth to free iOS\/Android app with programmable text\/email alarm notifications\u003c\/li\u003e\n\u003cli\u003ePanic and man-down alarms; stealth mode for law enforcement\u003c\/li\u003e\n\u003cli\u003eNon-compliance indicator; 3 user-adjustable alarm levels; simple 2-button operation\u003c\/li\u003e\n\u003cli\u003eLarge auto-backlit, auto-rotating display; impact-resistant body\u003c\/li\u003e\n\u003cli\u003eLi-ion: 25 hours operation, full charge in 3 hours; alkaline option; IP66\/68; 3-year warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 x 2.6 x 1.06 in; 4.58 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP66\/68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRun time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 h (Li-ion), 3 h charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications (manufacturer)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003ch3\u003eDetectable Gases\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGas\u003c\/td\u003e\n\u003ctd\u003eMeasuring Range\u003cbr\u003e(Increments)\u003c\/td\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003eStatement\u003c\/td\u003e\n\u003ctd\u003ePreset Alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e Sensor Slot 1: Carbon Monoxide (CO) \u0026amp; Hydrogen sulfide (H2S) *Interchangeable\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eH2S \/ CO\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eDual EC\u003c\/td\u003e\n\u003ctd\u003e0 ~ 2000 ppm\u003cbr\u003e(1 ppm)\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading\u003cbr\u003eor ± 5 ppm CO\u003c\/td\u003e\n\u003ctd\u003eA1: 25 ppm│ A2: 50 ppm │A3:1200 ppm│TWA: 25 ppm│ STEL: 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0 ~ 200.0 ppm\u003cbr\u003e(0.1 ppm)\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading\u003cbr\u003eor ± 2 ppm H2S\u003c\/td\u003e\n\u003ctd\u003eA1: 5 ppm│ A2: 30 ppm│ A3: 100 ppm│TWA: 1.0 ppm│ STEL: 5.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e H2S\u003cbr\u003eOnly \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0 ~ 200.0 ppm\u003cbr\u003e(0.1 ppm)\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading\u003cbr\u003eor ± 2 ppm H2S\u003c\/td\u003e\n\u003ctd\u003eA1: 5 ppm│ A2: 30 ppm│ A3: 100 ppm│TWA: 1.0 ppm│ STEL: 5.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CO\u003cbr\u003eH2 Compensated \u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0 ~ 2,000 ppm\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading\u003cbr\u003eor ± 2 ppm CO\u003c\/td\u003e\n\u003ctd\u003eA1: 25 ppm│ A2: 50 ppm │A3: 1200 ppm│TWA: 25 ppm│ STEL: 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e Sensor Slot 2: Combustibles (Methane as standard)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH4 \/ HC\u003c\/td\u003e\n\u003ctd\u003eCatalytic\u003c\/td\u003e\n\u003ctd\u003e0 ~ LEL (1% LEL)\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading\u003cbr\u003eor ± 2 % LEL\u003c\/td\u003e\n\u003ctd\u003e1st: 10% LEL │ 2nd: 25% LEL3rd: 50% LEL │ Over:100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e Sensor Slot 3: Oxygen (O2)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO2\u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40.0% Vol.\u003cbr\u003e(0.10%)\u003c\/td\u003e\n\u003ctd\u003e± 0.5% O2\u003c\/td\u003e\n\u003ctd\u003eLow 1: 19.5%│ Low 2: 18.0%│ High: 23.5%│ Over: 40.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e Sensor Slot 4: Toxics \u0026amp; CO2 *Interchangeable\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCN\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0 ~ 30.0 ppm\u003cbr\u003e(0.1 ppm)\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e± 10% of reading\u003cbr\u003eor ± 5 % of full scale\u003c\/td\u003e\n\u003ctd\u003eA1: 5.0 ppm│ A2: 10.00 ppm │ A3: 30.00 ppm│ TWA: 4.7 ppm\u003cbr\u003e│ STEL: 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO2\u003c\/td\u003e\n\u003ctd\u003e0 ~ 20.00 ppm\u003cbr\u003e(0.05 ppm)\u003c\/td\u003e\n\u003ctd\u003eA1: 2.00 ppm│ A2: 4.00 ppm │ A3: 20.00 ppm│ TWA: 0.20 ppm\u003cbr\u003e│ STEL: 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePH3\u003c\/td\u003e\n\u003ctd\u003e0 ~ 20.00 ppm (0.01 ppm)\u003c\/td\u003e\n\u003ctd\u003eA1: 0.30 ppm │ STEL: 1.0 ppm │ A2: 0.60 ppm │ TWA: 0.30 ppm │A3: 0.60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSO2\u003c\/td\u003e\n\u003ctd\u003e0 ~ 100.0 ppm\u003cbr\u003e(0.05 ppm)\u003c\/td\u003e\n\u003ctd\u003eA1: 2 ppm│ A2: 5 ppm│ A3: 100 ppm│ TWA: 0.25 ppm│ STEL: 0.25ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 %\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eIR\u003c\/td\u003e\n\u003ctd\u003e0 ~ 10.0% Vol.\u003cbr\u003e(0.01%)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e± 5% of reading\u003cbr\u003eor ± 2 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 0.50% Vol.│ A2: 3.00% Vol. │A3: 4.00% Vol.│ TWA: 0.50% Vol.│ STEL: 3.00% Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2 ppm\u003c\/td\u003e\n\u003ctd\u003e0 ~ 10,000 ppm\u003cbr\u003e(20 ppm)\u003c\/td\u003e\n\u003ctd\u003eA1: 5,000 ppm│ A2: N\/A │TWA: N\/A│STEL: N\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003ch3\u003eCommon Specifications\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Method\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDiffusion sampling standard\u003cbr\u003e(hand aspirator or clip-on motorized pump optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eFull dot LCD with Autobacklight\u003cbr\u003eand Autorotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eAlarm Types\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGas Alarm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTrouble Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cul\u003e\n\u003cli\u003e2 increasing alarms\u003c\/li\u003e\n\u003cli\u003eSTEL\u003c\/li\u003e\n\u003cli\u003eTWA\u003c\/li\u003e\n\u003cli\u003eOver scale alarm\u003c\/li\u003e\n\u003cli\u003eO2 decreasing\/\u003cbr\u003eincreasing\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cul\u003e\n\u003cli\u003eSensor disconnection\u003c\/li\u003e\n\u003cli\u003eLow battery\u003c\/li\u003e\n\u003cli\u003eCircuit error\u003c\/li\u003e\n\u003cli\u003eCalibration range error\u003c\/li\u003e\n\u003cli\u003eCal or bump due alarm\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"4\"\u003e• Man Down Alarm\u003cbr\u003e• Panic Alarm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eDisplay of Alarm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGas Alarm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eTrouble Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cul\u003e\n\u003cli\u003eFlashing LED’s\u003c\/li\u003e\n\u003cli\u003eContinuous buzzer (100 db @ 30cm)\u003c\/li\u003e\n\u003cli\u003eFlashing gas value\u003c\/li\u003e\n\u003cli\u003eVibration\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u003cul\u003e\n\u003cli\u003eFlashing LED’s\u003c\/li\u003e\n\u003cli\u003eIntermittent buzzer (95 db @ 30cm)\u003c\/li\u003e\n\u003cli\u003eDisplay of error message\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eOperating Temp. \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-20°C ~ +50°C\u003cbr\u003e[ -4°F ~ +122°F ] 10 to 90% RH, non-condensing (continuous environment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"4\"\u003e-40°C ~ +60°C\u003cbr\u003e[ -40°F ~ +140°F ] 0 to 95% RH, non-condensing\u003cbr\u003e(temporary environment)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eWithin 30 seconds (T90)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eConfig\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eLi-ion\u003c\/td\u003e\n\u003ctd\u003eAlkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-gas + EC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25 hours\u003c\/td\u003e\n\u003ctd\u003e16 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-gas + IR\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e16 hours\u003c\/td\u003e\n\u003ctd\u003e7 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.9” W x 2.6” H x 1.06” D\u003cbr\u003e(Approx. 73 W x 65 H x 26 D mm), 4.58oz (with rubber boot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eExplosion proof, dust and water resistant to IP-66\/68 (2m,1h) approval. Drop height 23 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBluetooth Communication\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eBLE: with iOS and Android phone app: RK Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDatalogging\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eLogs user ID, station ID, Calibration \u0026amp; Bump Test history, Alarm Events \u0026amp;\u003cbr\u003eAlarm Trends\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eAlligator clip, protective rubber boot, charger, calibration adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cul\u003e\n\u003cli\u003ePadded carrying case\u003c\/li\u003e\n\u003cli\u003eRP-3R Attachable sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available)\u003c\/li\u003e\n\u003cli\u003eUSB to IrDA downloading cable for datalogger\u003c\/li\u003e\n\u003cli\u003eSDM-3R calibration station\u003c\/li\u003e\n\u003cli\u003eHand aspirator\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Design \/ Approvals\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eATEX, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eThree years material and workmanship including sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-PAC-C\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39468974473251,"sku":"72-PAC-C","price":1816.45,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/GX-3R-Pro-Gas-Detector-BT-russmillsafety.com.png?v=1794189726"},{"product_id":"sdm-3r-calibration-station","title":"SDM-3R Calibration Station by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e SDM-3R calibration station for GX-3R and GX-3R Pro.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStand-alone charge, bump test, calibrate and alarm check\u003c\/li\u003e\n\u003cli\u003eAuto on\/off of gas detector; 3 gas inputs\u003c\/li\u003e\n\u003cli\u003eUp to 10 modules; records to USB, PC or network\u003c\/li\u003e\n\u003cli\u003eIncludes 1 solenoid, AC adapter, flash drive, USB cable, tubing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC adapter 100–240 VAC; 5.99 VDC 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor, 0°C to 40°C, \u0026lt;95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecords (stand-alone)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 calibrations, 214 bump tests or 469 alarm checks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows 7, 8, 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eVideos\u003c\/h3\u003e\n\u003ciframe width=\"350\" height=\"225\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/hXzEXVv16zY?controls=0\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 81-SDM3R101\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39469090930723,"sku":"81-SDM3R101","price":1747.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/SDM-3R-calibration-station-2-russmill.com.png?v=1794189726"},{"product_id":"smallest-single-gas-monitor-03-series-by-rki-instruments","title":"Smallest Single Gas Monitor - 03 Series by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e 03 Series single-gas monitors (GP-03 LEL, OX-03 O2, CO-03 CO, HS-03 H2S): pocket-size personal protection from combustible hydrocarbons, oxygen deficiency, hydrogen sulfide or carbon monoxide.\u003c\/p\u003e\n\u003cp\u003eModels: CO - CO-03\/ 0-500 ppm CO\/ alligator clip\/ alkaline batteries, H2S - HS-03\/ 0-100 ppm H2S\/ alligator clip\/ alkaline batteries, O2 - OX-03\/ 0-40% O2\/ alligator clip\/ alkaline batteries, LEL - GP-03\/ 0-100% LEL\/ alligator clip\/ alkaline batteries.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperates 3,000 hours on alkaline (GP-03 up to 35 hours)\u003c\/li\u003e\n\u003cli\u003ePocket size 2.1 x 2.6 x 0.9 in; 2.8 oz\u003c\/li\u003e\n\u003cli\u003eIP-67\u003c\/li\u003e\n\u003cli\u003eData log from 5 to 300 hours\u003c\/li\u003e\n\u003cli\u003eAudible, visual and vibration alarms; automatic backlight\u003c\/li\u003e\n\u003cli\u003ePeak hold, STEL and TWA\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe: ATEX and CSA\u003c\/li\u003e\n\u003cli\u003eWarranty: 3 years H2S and CO; 2 years LEL and O2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications (manufacturer)\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Name \u003c\/td\u003e\n\u003ctd\u003eCO-03\u003c\/td\u003e\n\u003ctd\u003eHS-03\u003c\/td\u003e\n\u003ctd\u003eOX-03\u003c\/td\u003e\n\u003ctd\u003eGP-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Detected \u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003eHydrogen Sulfide (H2S)\u003c\/td\u003e\n\u003ctd\u003eOxygen (O2)\u003c\/td\u003e\n\u003ctd\u003eCombustible gas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Principle \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003cbr\u003e(Increments) \u003c\/td\u003e\n\u003ctd\u003e0 – 500 ppm\u003cbr\u003e(1 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003cbr\u003e(0.5 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 – 40%vol.\u003cbr\u003e(0.1% vol.)\u003c\/td\u003e\n\u003ctd\u003e0 – 100% LEL\u003cbr\u003e(1% LEL increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Set Points \u003c\/td\u003e\n\u003ctd\u003e1st 25 ppm\u003cbr\u003e2nd 50 ppm\u003cbr\u003eTWA 25 ppm\u003cbr\u003eSTEL 200 ppm\u003cbr\u003eOver 500 ppm\u003c\/td\u003e\n\u003ctd\u003e1st 5.0 ppm\u003cbr\u003e2nd 30.0 ppm\u003cbr\u003eTWA 1.0 ppm\u003cbr\u003eSTEL 5.0 ppm\u003cbr\u003eOver 100.0 ppm\u003c\/td\u003e\n\u003ctd\u003eLow 19.5% vol.\u003cbr\u003eHigh 23.5% vol.\u003cbr\u003eOver 40.0% vol.\u003c\/td\u003e\n\u003ctd\u003e1st 10% LEL\u003cbr\u003e2nd 50% LEL\u003cbr\u003eOver 100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Types \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cul\u003e\n\u003cli\u003eGas alarms: 1st and 2nd (user adjustable), OVER alarm, STEL and TWA\u003c\/li\u003e\n\u003cli\u003eTrouble alarms: Sensor connection, low battery circuit failure, and calibration range error\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Methods \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cul\u003e\n\u003cli\u003eGas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration\u003c\/li\u003e\n\u003cli\u003eTrouble alarm: Flashing LED’s, intermittent buzzer, and display of error message\u003c\/li\u003e\n\u003cli\u003eSTEL \u0026amp; TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Sampling \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eT90 in 30 seconds\u003c\/td\u003e\n\u003ctd\u003eT90 in 20 seconds\u003cbr\u003e(Alarms within\u003cbr\u003e5 seconds when exposed to 12% O2)\u003c\/td\u003e\n\u003ctd\u003eT90 in 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003ewhich ever is greater \u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or ± 5 ppm CO\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or ± 2 ppm H2S\u003c\/td\u003e\n\u003ctd\u003e±0.5% O2\u003c\/td\u003e\n\u003ctd\u003e± 5 of reading or\u003cbr\u003e± 2% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Options\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAlkaline dry cell (2-AAA size)\u003c\/td\u003e\n\u003ctd\u003eAlkaline dry cell (2-AAA size)\u003cbr\u003eNi-MH battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAlkaline dry cell: more than 3,000 hours\u003cbr\u003e(at 25°C, no backlight)\u003c\/td\u003e\n\u003ctd\u003eAlkaline: 35 hrs\u003cbr\u003eNi-MH: 30 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eATEX\/IECEx approved. CSA classified, “C\/US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; Weight \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDigital LCD, gas name \u0026amp; concentration, auto backlighting during alarm, operation icon, battery icon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp. \u0026amp; Humidity \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-4°F ~ 122°F (-20°C ~ 50°C);\u003cbr\u003eHumidity below 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cul\u003e\n\u003cli\u003eRubber protective boot\u003c\/li\u003e\n\u003cli\u003eAlligator clip\u003c\/li\u003e\n\u003cli\u003eData logging software\u003c\/li\u003e\n\u003cli\u003eAlkaline batteries\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cul\u003e\n\u003cli\u003eCalibration adapter\u003c\/li\u003e\n\u003cli\u003eCharger unit\u003c\/li\u003e\n\u003cli\u003eCalibration kit\u003c\/li\u003e\n\u003cli\u003eBelt clip\u003c\/li\u003e\n\u003cli\u003eData logging download cable\u003c\/li\u003e\n\u003cli\u003eWrist strap\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Functions \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e\u003cul\u003e\n\u003cli\u003eManual backlight for LCD (automatically lit during alarm)\u003c\/li\u003e\n\u003cli\u003ePeak hold, STEL \u0026amp; TWA\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 Year warranty\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCO - CO-03\/ 0-500 ppm CO\/ alligator clip\/ alkaline batteries — SKU: 73-0060 — EAN: 2970102862203\u003c\/li\u003e\n\u003cli\u003eH2S - HS-03\/ 0-100 ppm H2S\/ alligator clip\/ alkaline batteries — SKU: 73-0062 — EAN: 2970102862266\u003c\/li\u003e\n\u003cli\u003eO2 - OX-03\/ 0-40% O2\/ alligator clip\/ alkaline batteries — SKU: 72-0010 — EAN: 2970102862209\u003c\/li\u003e\n\u003cli\u003eLEL - GP-03\/ 0-100% LEL\/ alligator clip\/ alkaline batteries — SKU: 72-0037 — EAN: 2970102862204\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"CO - CO-03\/ 0-500 ppm CO\/ alligator clip\/ alkaline batteries","offer_id":39474530811939,"sku":"73-0060","price":589.7,"currency_code":"USD","in_stock":true},{"title":"H2S - HS-03\/ 0-100 ppm H2S\/ alligator clip\/ alkaline batteries","offer_id":39474523996195,"sku":"73-0062","price":589.7,"currency_code":"USD","in_stock":true},{"title":"O2 - OX-03\/ 0-40% O2\/ alligator clip\/ alkaline batteries","offer_id":39474523930659,"sku":"72-0010","price":589.7,"currency_code":"USD","in_stock":true},{"title":"LEL - GP-03\/ 0-100% LEL\/ alligator clip\/ alkaline batteries","offer_id":39474523963427,"sku":"72-0037","price":673.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/series-03-gas-monitors-russmillsafety.com.png?v=1634133585"},{"product_id":"sdm-03-docking-and-calibration-station","title":"SDM-03 Docking and Calibration Station by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e SDM-03 docking and calibration station.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStand-alone charging, bump test and calibration (no PC)\u003c\/li\u003e\n\u003cli\u003eRecords to USB drive; PC software included\u003c\/li\u003e\n\u003cli\u003eUp to 10 modules on one PC; manifold to share regulators\u003c\/li\u003e\n\u003cli\u003ePictorial wall chart user guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 VDC (AC adapter 100–240 VAC included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndoor, -10°C to 40°C, \u0026lt;80% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstruments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e03 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecords\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 stand-alone; unlimited with software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePorts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCal gas, fresh air, exhaust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 81-SDM03\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39481892175907,"sku":"81-SDM03","price":1703.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rs-catalog-white-6613957607459-1.png?v=1794189726"},{"product_id":"gx-6000-pid-gas-monitor-by-rki-instruments","title":"GX-6000 PID Gas Monitor by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GX-6000 PID gas monitor (72-6ABX-C: LEL \/ O2 \/ H2S \/ CO \/ VOCs 0–6,000 ppm PID, with Li-ion battery pack and 100–240 VAC charger): simultaneously monitors up to 6 gases.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStandard 4 confined-space gases (combustibles, O2, CO, H2S) plus 2 interchangeable smart channels for PID, IR or super-toxic sensors\u003c\/li\u003e\n\u003cli\u003eSmallest 6-gas sample-draw monitor, with strong internal sample pump\u003c\/li\u003e\n\u003cli\u003e4 PID options: 10.0 eV, 10.6 eV (low or high range) and 11.7 eV lamps; any two can be installed; humidity resistant\u003c\/li\u003e\n\u003cli\u003ePID library of over 600 VOCs, with a 30-gas favourites list and 8 recently used\u003c\/li\u003e\n\u003cli\u003eBenzene-specific version using a pre-filter tube for low benzene levels\u003c\/li\u003e\n\u003cli\u003eOperating modes: Normal, Barhole, Inert, Leak Check (ppm), Snap Log and Benzene Specific\u003c\/li\u003e\n\u003cli\u003eMan-down and panic alarms; 5 bright LEDs on 3 sides, vibration and loud audible alarm\u003c\/li\u003e\n\u003cli\u003eLED flashlight; large auto-rotating LCD with peak-bar display\u003c\/li\u003e\n\u003cli\u003eLEL sensor protection mode\u003c\/li\u003e\n\u003cli\u003eRugged, lightweight IP-67 design with removable impact-resistant rubber boot\u003c\/li\u003e\n\u003cli\u003eInterchangeable battery packs; operates up to 14 hours\u003c\/li\u003e\n\u003cli\u003eField-replaceable sensors, batteries, filters and pump\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe ATEX \/ IECEx \/ cCSAus\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e Gases \u0026amp; Detectable Ranges \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eGas\u003c\/td\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003eReading Increment\u003c\/td\u003e\n\u003ctd\u003eAlarm Set Points\u003c\/td\u003e\n\u003ctd\u003eAccuracy (which ever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003ePID Sensors\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e10.6 Lamp\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e600 VOC’s\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 50,000 ppb\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e1 ppb: (\u0026lt; 5000 ppb) 10 ppb: (\u0026gt; 5,000 ppb)\u003c\/td\u003e\n\u003ctd\u003eA1: 5,000 ppb\u003c\/td\u003e\n\u003ctd rowspan=\"8\"\u003e± 10% of reading, ± 1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 10,000 ppb\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 6,000 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.1 ppm: (\u0026lt; 600 ppm) 1 ppm: (\u0026gt; 600 ppm)\u003c\/td\u003e\n\u003ctd\u003eA1: 400 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 1,000 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e10.0 Lamp\u003c\/td\u003e\n\u003ctd\u003eBenzene Specific\u003c\/td\u003e\n\u003ctd\u003e0.1 – 50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm)\u003c\/td\u003e\n\u003ctd\u003eNo Alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300 VOC’s\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm)\u003c\/td\u003e\n\u003ctd\u003eA1: 5 ppm A2: 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e11.7 Lamp\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eHigh Voltage Lamp\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 1000 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 400 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 1,000 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eGalvanic\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eOxygen (O2)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 40.0% Vol.\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd\u003eA1: 19.5 Vol.\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e± 0.5% O2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 23.5 Vol.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eElectro Chemical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"2\"\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e0 – 500 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 25 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e± 5% of reading or ± 5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 50 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eTWA 25 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eSTEL 200 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" colspan=\"2\"\u003eHydrogen Sulfide (H2S)\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e0 – 100.0 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e0.5 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 5.0 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e± 5% of reading or ± 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 30.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eTWA 1.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eSTEL 5.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e Toxics (EC Sensors) \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 400.0 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.5 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 25 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"10\"\u003e± 10% of reading or ± 5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 50 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 10.00 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.05 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 0.5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 1.0 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 10 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eNitrogen Dioxide (NO2)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 20.00 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e0.05 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 6 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eSulfur Dioxide (SO2)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 99.90 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 5 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eIR Sensors\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"6\" colspan=\"2\"\u003eCarbon Dioxide (CO2)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 10,000 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e20 ppm\u003c\/td\u003e\n\u003ctd\u003eA1: 5,000 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"8\"\u003e± 5% of reading or ± 2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eTWA 5,000 ppm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e0 – 10.00% Vol.\u003c\/td\u003e\n\u003ctd rowspan=\"4\"\u003e0.02%\u003c\/td\u003e\n\u003ctd\u003eA1: 0.50% Vol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 3.00% Vol\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eSTEL 3.00% Vol\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eTWA 0.50% Vol\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMethane (CH4)\u003c\/td\u003e\n\u003ctd\u003e0 – 100% LEL 0 – 100% Vol.\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e1% LEL\/ 0.5% Vol\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eA1: 10% LEL A2: 50% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eHydrocarbons\u003c\/td\u003e\n\u003ctd\u003e0 – 100% LEL 0 – 30% Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eCatalytic\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003eHydrocarbons (CH4, std)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e0 – 100% LEL\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e1% LEL\u003c\/td\u003e\n\u003ctd\u003eA1: 10%LEL\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e± 5% of reading or ± 2% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003eA2: 50%LEL\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"4\"\u003e Common Specifications \u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eAlarm Types \u003c\/td\u003e\n\u003ctd\u003eGas alarm\u003c\/td\u003e\n\u003ctd\u003eMan-down\u003c\/td\u003e\n\u003ctd\u003eTrouble\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow and high adjustable\u003c\/td\u003e\n\u003ctd\u003e1st – self reset 2nd – latching\u003c\/td\u003e\n\u003ctd\u003eLow flow Sensor connection Low battery Circuit error Calibration range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Method\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eSample draw pump, flow rate 0.45 LPM, 50 foot sample range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDigital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible Alarm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e95 dB at 1 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEnglish, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp. \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eDust and water resistant with IP-67 approval (exclude sample hose and probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Safety Design \/Approvals \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eExplosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e  Standard Features \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User \u0026amp; station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero \/ Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e• Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic \u0026amp; dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e• SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTwo years material (including sensors) and workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-6ABX-C\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39506963202083,"sku":"72-6ABX-C","price":6939.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/GX-6000-PID-Gas-Monitor-russmillsafety.com.png?v=1794189726"},{"product_id":"gx-2012-confined-space-gas-monitor-by-rki-instruments","title":"GX-2012 Confined Space Gas Monitor by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GX-2012 confined space gas monitor (72-0292-01-B: 1 sensor, LEL base, alkaline and Li-ion battery packs with 100–240 VAC charger): multiple tools in one instrument.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e3 operating modes: Normal (confined space safety monitoring), Leak Check (leak investigation, with ppm leak detector and CO display) and Bar Hole (underground leak checks)\u003c\/li\u003e\n\u003cli\u003eMonitors ppm\/% LEL, % volume methane, O2, CO and H2S; with optional TC sensor measures 0–100% volume methane and auto-ranges from % LEL to % volume, ideal for line purge testing\u003c\/li\u003e\n\u003cli\u003eRKI's smallest personal 1–5 sensor monitor with built-in sample pump (up to 50 ft); weighs only 12.3 oz\u003c\/li\u003e\n\u003cli\u003eLarge LCD shows all gas readings, battery level and time; automatic backlight in alarm\u003c\/li\u003e\n\u003cli\u003eVibration, visual and audible alarms, latching or non-latching; visual\/audible pulses change with gas concentration\u003c\/li\u003e\n\u003cli\u003eContinuous self-checks for sensor connections, low battery, circuit trouble, low flow and calibration errors\u003c\/li\u003e\n\u003cli\u003eInterchangeable Li-ion or alkaline battery packs, replaced without tools\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe, ATEX\/IECEx\/CE or CSA\/CE (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Detected\u003c\/td\u003e\n\u003ctd\u003eCombustible Gases\u003cbr\u003e(Methane as standard)\u003c\/td\u003e\n\u003ctd\u003e% Volume\u003cbr\u003eMethane\u003c\/td\u003e\n\u003ctd\u003eOxygen (O2)\u003c\/td\u003e\n\u003ctd\u003eHydrogen Sulfide (H2S)\u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Principle\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion\u003c\/td\u003e\n\u003ctd\u003eThermal conductivity\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectrochemical cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0 ~ 100% LEL\u003cbr\u003e0 ~ 500 \/ 1,000 \/ 2,000 \/ 5,000 ppm\u003c\/td\u003e\n\u003ctd\u003e0 ~ 100% Vol.\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40% Vol.\u003c\/td\u003e\n\u003ctd\u003e0 ~ 100 ppm\u003cbr\u003e(optional 0-500 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy Statement\u003cbr\u003e(whichever is greater)\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or\u003cbr\u003e± 2% LEL(LEL mode only)\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or ± 2% of full scale\u003c\/td\u003e\n\u003ctd\u003e± 0.5% O2\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or ± 2 ppm H2S\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or ± 5 ppm CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Method\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eInternal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eDigital LCD with 7 segments, auto backlight during alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreset Alarms\u003cbr\u003e(User Adjustable)\u003c\/td\u003e\n\u003ctd\u003e1st alarm 10% LEL\u003cbr\u003e2nd alarm 50% LEL\u003cbr\u003eOver alarm 100% LEL\u003c\/td\u003e\n\u003ctd\u003eNo alarms for\u003cbr\u003e% Vol. CH4\u003c\/td\u003e\n\u003ctd\u003eLow alarm 19.5% High alarm 23.5% Over alarm 40.0%\u003c\/td\u003e\n\u003ctd\u003e1st 5 ppm\u003cbr\u003e2nd 30 ppm\u003cbr\u003eTWA 10 ppm\u003cbr\u003eSTEL 15 ppm\u003cbr\u003eOver 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1st 25 ppm\u003cbr\u003e2nd 50 ppm\u003cbr\u003eTWA 25 ppm\u003cbr\u003eSTEL 200 ppm\u003cbr\u003eOver 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms Types\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eGas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER\u003cbr\u003eTrouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Methods\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eGas alarms: Flashing lights, two tone buzzer, and vibration\u003cbr\u003eTrouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp. \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e-20°C to +50°C (-4°F to 122°F)\u003cbr\u003e0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eWithin 30 seconds (T90)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAlkaline battery: 15 hours Li-Ion battery: 10 hours\u003cbr\u003e70°F (21°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eLi-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eApprox. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eHigh dust \u0026amp; water resistant design. RFI shielded high impact plastic with protective rubber overmolding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eFive buttons: POWER \/ ENTER, DISPLAY, AIR, RESET, SHIFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u003cul\u003e\n\u003cli\u003e•Belt clip\u003c\/li\u003e\n\u003cli\u003eRubber nozzle, 3.5”\u003c\/li\u003e\n\u003cli\u003eDatalogging software\u003c\/li\u003e\n\u003cli\u003e10” Probe\u003c\/li\u003e\n\u003cli\u003eManual\u003c\/li\u003e\n\u003cli\u003eQuick reference card\u003c\/li\u003e\n\u003cli\u003e10’ Hose\u003c\/li\u003e\n\u003cli\u003eTraining CD\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u003cul\u003e\n\u003cli\u003eSDM-2012 calibration stations\u003c\/li\u003e\n\u003cli\u003eCalibration kit\u003c\/li\u003e\n\u003cli\u003eLi-Ion battery pack\u003c\/li\u003e\n\u003cli\u003eAC or DC Charger\u003c\/li\u003e\n\u003cli\u003eSample draw hoses (10’ standard, up to 100’ max. available)\u003c\/li\u003e\n\u003cli\u003eCarrying case\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurations\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e1, 2, 3, 4, or 5 sensor units\u003cbr\u003eLi-Ion or alkaline battery pack options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eTwo years material and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-0292-01-B\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39507144015907,"sku":"72-0292-01-B","price":1939.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/GX-2012-Confined-Space-Gas-Monitor-russmillsafety.com.png?v=1637010538"},{"product_id":"smallest-toxic-gas-monitor-04-series-by-rki-instruments","title":"Smallest Toxic Gas Monitor - 04 Series by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e 04 Series toxic single-gas monitor, designed to operate for many years with field-replaceable sensors and filters.\u003c\/p\u003e\n\u003cp\u003eModels: HS-04, CO-04, OX-04.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2 user-adjustable preset alarms with visual, audible and vibration alarms as standard\u003c\/li\u003e\n\u003cli\u003eHCN, NO2, PH3 and SO2 versions run continuously for at least 3,000 hours on 2 AAA alkaline batteries\u003c\/li\u003e\n\u003cli\u003eInexpensive, field-replaceable sensors interchangeable with RKI GX-3R, GX-3R Pro and GasWatch 3\u003c\/li\u003e\n\u003cli\u003eSensor life expectancy over 3 years, backed by a 3-year warranty\u003c\/li\u003e\n\u003cli\u003eImpact, dust and water resistant (IP-67)\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe: ATEX\/IECEx, and QPS to U.S. and Canadian standards for Class I, Division 1, Groups A, B, C and D\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Name\u003c\/td\u003e\n\u003ctd\u003eSC-04 HCN\u003c\/td\u003e\n\u003ctd\u003eSC-04 NO2\u003c\/td\u003e\n\u003ctd\u003eSC-04 PH3\u003c\/td\u003e\n\u003ctd\u003eSC-04 SO2\u003c\/td\u003e\n\u003ctd\u003eCO-04 (-H2)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCX-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Detected\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide\u003c\/td\u003e\n\u003ctd\u003eNitrogen Dioxide\u003c\/td\u003e\n\u003ctd\u003ePhosphine\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide\u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003eO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Principle\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart#\u003c\/td\u003e\n\u003ctd\u003e73-0071\u003c\/td\u003e\n\u003ctd\u003e73-0073\u003c\/td\u003e\n\u003ctd\u003e73-0079\u003c\/td\u003e\n\u003ctd\u003e73-0083\u003c\/td\u003e\n\u003ctd\u003e73-0067\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e73-0069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003cbr\u003e(Increments)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 30.0 ppm\u003cbr\u003e(0.1 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 20.00 ppm\u003cbr\u003e(0.05 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 20.00 ppm\u003cbr\u003e(0.01 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 100.0 ppm\u003cbr\u003e(0.05 ppm)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 ~ 2000 ppm\u003cbr\u003e(1 ppm)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 40%\u003cbr\u003e(0.1%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Set Points\u003c\/td\u003e\n\u003ctd\u003e1st: 5.0 ppm\u003cbr\u003e2nd: 10.0 ppm\u003cbr\u003e3rd: 30.0 ppm\u003cbr\u003eTWA: 4.7 ppm\u003cbr\u003eSTEL: 10 ppm\u003c\/td\u003e\n\u003ctd\u003e1st: 2.00 ppm\u003cbr\u003e2nd: b4.00 ppm\u003cbr\u003e3rd: 20.00 ppm\u003cbr\u003eTWA: 0.50 ppm\u003cbr\u003eSTEL: 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e1st: 0.30 ppm\u003cbr\u003e2nd: 0.60 ppm\u003cbr\u003e3rd: 0.60 ppm\u003cbr\u003eTWA: 0.30 ppm\u003cbr\u003eSTEL: 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e1st: 2.00 ppm\u003cbr\u003e2nd: 5.00 ppm\u003cbr\u003e3rd: 100.00 ppm\u003cbr\u003eTWA: 2.00 ppm\u003cbr\u003eSTEL 5.00 ppm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1st 25 ppm\u003cbr\u003e2nd 50 ppm\u003cbr\u003e3rd 1200 ppm\u003cbr\u003eTWA 25 ppm\u003cbr\u003eSTEL 200 ppm\u003c\/td\u003e\n\u003ctd\u003eL: 19.5 %\u003cbr\u003eLL: 18.0%\u003cbr\u003eH: 25.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Types\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eGas alarms: 1st, 2nd and 3rd (user adjustable), OVER alarm, STEL and TWA\u003cbr\u003eTrouble alarms: Sensor connection, low battery, circuit failure, and calibration range error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Methods\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eGas alarm: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration\u003cbr\u003eTrouble alarm: Flashing LED’s, intermittent buzzer, and display of error message\u003cbr\u003eSTEL \u0026amp; TWA alarms: Flashing LED’s, intermittent buzzer, flashing gas value, and vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Sampling\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eDiffusion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eT90 in 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003e(which ever is greater)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e± 10% of reading\u003cbr\u003eor ± 5 % of full scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e\u0026lt; 300 ppm ± 5 % of reading\u003cbr\u003e\u0026gt; 300 ppm ± 20 % of reading\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 25% ± 0.5 %\u003cbr\u003e\u0026gt; 25% ± 3.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eData Logging\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e10 second intervals = 10 hours, 5 minute intervals = 300 hours, 10 minute intervals = 600 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"7\"\u003eInstrument records alarms, alarm trends, gas readings, calibration \u0026amp; bump test history, instrument information and settings.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Options\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eAlkaline dry cell (2-AAA size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e3,000 hours (at 25°C, no backlight)\u003c\/td\u003e\n\u003ctd\u003e6,200 hours\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4,600 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eATEX\/IECEx approved. QPS classified, “C \/ US”, as intrinsically safe, Class I, Division 1, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eDust and water resistant with IP-67 rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions \u0026amp; Weight\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e2.1” W x 2.64” H x 0.94” D, (54 x 67 x 24 mm); 2.8 ounces (80 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003eDigital LCD, gas name \u0026amp; concentration, auto backlighting during alarm, operation icon, battery icon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp. \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e-4°F ~ 122°F (-20°C ~ 50°C);\u003cbr\u003eHumidity below 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e• Rubber protective boot • Alligator clip • Data logging software\u003cbr\u003e• Alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e• Calibration cap • Wrist strap\u003cbr\u003e• Calibration kit • Belt clip • Data logging download cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Functions\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e• Manual backlight for LCD (automatically lit during alarm)\u003cbr\u003e• Peak hold, STEL \u0026amp; TWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"7\"\u003e3 Year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHS-04 — SKU: 73-0063\u003c\/li\u003e\n\u003cli\u003eCO-04 — SKU: 73-0065\u003c\/li\u003e\n\u003cli\u003eOX-04 — SKU: 72-0018\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"HS-04","offer_id":39872381517859,"sku":"73-0063","price":352.25,"currency_code":"USD","in_stock":true},{"title":"CO-04","offer_id":39872381550627,"sku":"73-0065","price":342.25,"currency_code":"USD","in_stock":true},{"title":"OX-04","offer_id":39872381583395,"sku":"72-0018","price":342.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Smallest-Toxic-Gas-Monitor-04-Series-russmillsafety.com.png?v=1794189726"},{"product_id":"smallest-gas-monitor-gaswatch-3-by-rki-instruments","title":"Smallest Gas Monitor - GasWatch 3 by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GasWatch 3: the world's smallest and lightest single-gas monitor, weighing just 1.6 oz, worn on the wrist or clipped into your breathing zone.\u003c\/p\u003e\n\u003cp\u003eVersions: O2 - Galvanic sensor with alligator clip, H2S with alligator clip, CO - electrochemical sensor with alligator clip, CO with H2 compensated sensor and alligator clip, CO \/ O2 combination with alligator clip.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e5 versions: O2 [GW-3(O2)], CO [GW-3(CO)], H2S [GW-3(H2S)], H2-compensated CO [GW-3(C-)] for steel mills, refineries and other hydrogen environments, and dual CO\/O2 [GW-3(CX)]\u003c\/li\u003e\n\u003cli\u003eField-replaceable coin-type lithium battery: over 4,000 hours continuous operation (H2-compensated CO up to 2,500 h; CO\/O2 up to 2,000 h)\u003c\/li\u003e\n\u003cli\u003e3-year warranty* (2 years for O2 sensor)\u003c\/li\u003e\n\u003cli\u003eLight, compact watch-type design; watch band, clip-on or alligator clip with 360° rotation\u003c\/li\u003e\n\u003cli\u003eAutomatic backlight during alarm\u003c\/li\u003e\n\u003cli\u003eSturdy IP-66\/68 design: water, dust and RF resistant\u003c\/li\u003e\n\u003cli\u003eNon-compliance indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eGW-3 (HS)\u003cbr\u003eHydrogen Sulfide\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eGW-3 (CO)\u003cbr\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eGW-3 (C-)\u003cbr\u003eH2 Compensated CO\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eGW-3 (CX) (Dual Sensor)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eGX-3 (O2)\u003cbr\u003eOxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection\u003cbr\u003ePrinciple\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eEC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDual EC\u003c\/td\u003e\n\u003ctd\u003eGalvanic Cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003cbr\u003e(Increments)\u003c\/td\u003e\n\u003ctd\u003e0 ~ 30 ppm (0.1)\u003cbr\u003e30 ~ 100 ppm (1)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0 ~ 300 ppm (1)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0 ~ 25.0% Vol. (0.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Range\u003c\/td\u003e\n\u003ctd\u003e100 ~ 200 ppm (1)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e310 ~ 2,000 ppm (10)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e25 ~ 40.0% Vol. (0.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoints\u003c\/td\u003e\n\u003ctd\u003e1st: 5.0 ppm\u003cbr\u003e2nd: 30.0 ppm\u003cbr\u003e3rd: 100.0 ppm\u003cbr\u003eTWA: 1.0 ppm\u003cbr\u003eSTEL: 5.0 ppm\u003cbr\u003eOVER: 200.0 ppm\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1st: 25 ppm\u003cbr\u003e2nd: 50 ppm\u003cbr\u003e3rd: 1200 ppm\u003cbr\u003eTWA: 25 ppm\u003cbr\u003eSTEL: 200 ppm\u003cbr\u003eOVER: 2,000 ppm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eL: 19.5% Vol.\u003cbr\u003eLL: 18.0% Vol.\u003cbr\u003eH: 23.5% Vol.\u003cbr\u003eOVER: 40.0% Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e-20 °C to +50 °C (no sudden changes)\u003cbr\u003e(Approx. 15-minute temporary use environment: -20 °C to +60 °C)\u003cbr\u003e[no sudden changes]\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +50 °C\u003cbr\u003e(no sudden changes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e10 to 90 %RH (no condensation)\u003cbr\u003e(Approx. 15-minute temporary use environment: 0 to 95 %RH)\u003cbr\u003e[no condensation]\u003c\/td\u003e\n\u003ctd\u003e10 to 90 %RH\u003cbr\u003e(no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous\u003cbr\u003eOperating Time\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eApprox. 4,000 hours\u003c\/td\u003e\n\u003ctd\u003eApprox. 2,500 hours\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eApprox. 2,000 hours\u003c\/td\u003e\n\u003ctd\u003eApprox. 4,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Method\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eDiffusion Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypes of Alarm\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eGas alarms: Three-step alarms, STEL alarm, TWA alarm, OVER alarm   Fault alarms: Sensor connection \/ disconnection, low battery level, calibration failure, clock abnormality, system abnormality \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Indications\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eAuto-reset or self latching   Lamp flashing, intermittent buzzer sounding, gas concentration readout blinking, vibration \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eCR2450 coin-type lithium ion battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eIntrisically safe explosion-proof construction (Ex ia IIC T4 Ga) , IP 66\/68 (6.6ft, 1h) (2m, 1h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eATEX, IECEx, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension \u0026amp; Weight\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e2.5″ W x 1.6″ H x .86″ D (Approx 63 mm W x 42mm H x 22mm D) , 1.6 ounces (approx. 45g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eData logger, vibration, STEL alarm, TWA alarm, quick calibration, peak value display, temperature display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003cbr\u003eAccessories\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eCR2450 coin-type lithium-ion battery, Spring pins (used to mount accessories on to the rear face),\u003cbr\u003eWatch band, Alligator clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003cbr\u003eAccessories\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eHeat-resistant case, Dust filter, CF-1821 filter (for CO sensor), CF-A13i-1 humidity control filter (for H2S sensor), Calibration adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eO2 - Galvanic sensor with alligator clip — SKU: 72-0012\u003c\/li\u003e\n\u003cli\u003eH2S with alligator clip — SKU: 72-0022\u003c\/li\u003e\n\u003cli\u003eCO - electrochemical sensor with alligator clip — SKU: 72-0023\u003c\/li\u003e\n\u003cli\u003eCO with H2 compensated sensor and alligator clip — SKU: 72-0025\u003c\/li\u003e\n\u003cli\u003eCO \/ O2 combination with alligator clip — SKU: 72-0026\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"O2 - Galvanic sensor with alligator clip","offer_id":39510484647971,"sku":"72-0012","price":758.2,"currency_code":"USD","in_stock":true},{"title":"H2S with alligator clip","offer_id":39510484680739,"sku":"72-0022","price":758.2,"currency_code":"USD","in_stock":true},{"title":"CO - electrochemical sensor with alligator clip","offer_id":39510484713507,"sku":"72-0023","price":758.2,"currency_code":"USD","in_stock":true},{"title":"CO with H2 compensated sensor and alligator clip","offer_id":39510484746275,"sku":"72-0025","price":1042.5,"currency_code":"USD","in_stock":true},{"title":"CO \/ O2 combination with alligator clip","offer_id":39510497656867,"sku":"72-0026","price":1042.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Smallest-Gas-Monitor-GasWatch-3-russmillsafety.com.png?v=1637250616"},{"product_id":"eagle-2-multi-gas-detector-lel-o2-h2s-co-voc-toxics-by-rki-instruments","title":"Eagle 2 Multi Gas Detector (LEL, O2, H2S, CO, VOC \u0026 Toxics) by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Eagle 2 (722-001, LEL \u0026amp; ppm \/ O2) 6-gas sample-draw monitor: the solution for just about any portable gas monitoring situation, well beyond standard confined-space LEL, O2, H2S and CO protection.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMonitors up to 6 gases; ppm, % LEL or % vol auto-ranging combustible detection\u003c\/li\u003e\n\u003cli\u003eEasy access to auto-calibration, alarm silence, demand zero, peak hold and methane elimination\u003c\/li\u003e\n\u003cli\u003eTwo user-adjustable alarm levels per channel (latching or self-resetting) plus TWA and STEL for toxics\u003c\/li\u003e\n\u003cli\u003eOptional PID for low or high ppm VOCs (0–50 and 0–2,000 ppm) with Fence Electrode Technology\u003c\/li\u003e\n\u003cli\u003eOptional TC sensor for % vol CH4 and H2; IR sensors for CO2, CH4 and HC; H2-specific LEL\/ppm sensor\u003c\/li\u003e\n\u003cli\u003eSmart plug-and-play toxic sensors: NH3, AsH3, Cl2, HCN, PH3, SO2\u003c\/li\u003e\n\u003cli\u003eStrong internal pump draws samples up to 125 ft, with low-flow shut-off and alarm\u003c\/li\u003e\n\u003cli\u003eOver 18 hours on alkaline or 20 hours on NiMH batteries\u003c\/li\u003e\n\u003cli\u003eDatalogging standard on all sensors\u003c\/li\u003e\n\u003cli\u003eInternal hydrophobic dust filter; external probe with hydrophobic filter\u003c\/li\u003e\n\u003cli\u003eMultilingual (5 languages); RFI\/EMI, chemical and weather-resistant enclosure\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe design, CSA approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfined space entry\u003c\/li\u003e\n\u003cli\u003eEPA Method 21 fugitive emission monitoring of VOC leaks from process equipment\u003c\/li\u003e\n\u003cli\u003eEnvironmental applications (methane elimination)\u003c\/li\u003e\n\u003cli\u003eTank testing with float probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eWeatherproof, chemical resistant, RFI \/ EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water \u0026amp; dust resistant equivalent to IP64.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.5” L x 5.25” W x 5.875” H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.8 Lbs (standard 4 gas with batteries).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Principle\u003c\/td\u003e\n\u003ctd\u003eCatalytic combustion, electrochemical cell, galvanic cell, infrared, Photoionization detector, and thermal conductivity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Method\u003c\/td\u003e\n\u003ctd\u003ePowerful, long-life internal pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand, with adjustable time.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eReadout can display in 5 languages (English, French, German, Italian, or Spanish).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarms\u003c\/td\u003e\n\u003ctd\u003e2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Method\u003c\/td\u003e\n\u003ctd\u003eBuzzer 95 dB at 30 cm, four high intensity LED’s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003e4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL\/ppm, alarm silence, peak hold, TWA\/STEL values, battery status, conversion factors, and many other features.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation\u003c\/td\u003e\n\u003ctd\u003eAt 70°F, 18 hours using alkaline batteries, or 20 hours using NiMH.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e4 alkaline or NiMH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp. \u0026amp; Humidity\u003c\/td\u003e\n\u003ctd\u003e-20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eIP-64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e30 Seconds to 90% (for most gases) using standard 5 ft hose.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eIntrinsically Safe, Class I, Groups A, B, C, D. Approvals: CSA \/ CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Accessories\u003c\/td\u003e\n\u003ctd\u003eShoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Accessories\u003c\/td\u003e\n\u003ctd\u003e• Dilution fitting (50\/50) • NiMH batteries • Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours) • Continuous operation adapter, 115 VAC or 12 VDC • Extension hoses • IRDA cable for datalogging download\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eTwo year material and workmanship, one year for PID sensor.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 722-001\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39510509420579,"sku":"722-001","price":4412.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Eagle-2-Multi-Gas-Detector-russmillsafety.com.png?v=1794189726"},{"product_id":"beacon-110-single-channel-wall-mount-controller-by-rki-instruments","title":"Beacon 110 Single Channel Wall Mount Controller by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Beacon 110 single-channel wall-mount controller (72-2110RK-02, small red light, no sensor): gas detection simplified, for one point of detection.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowerful, low-cost, microprocessor-controlled fixed system controller; simple to install and operate\u003c\/li\u003e\n\u003cli\u003eAccepts RKI LEL, O2, H2S or CO direct-connect sensors, or any 4-20 mA transmitter (2 or 3 wire, 24 VDC)\u003c\/li\u003e\n\u003cli\u003eSensors mount at the housing or wire remotely; long-life sensors (2+ years typical)\u003c\/li\u003e\n\u003cli\u003eTwo programmable alarm levels; audible alarm with reset button; built-in trouble alarm with relay\u003c\/li\u003e\n\u003cli\u003e10 A form C relays directly power external alarms and horns\u003c\/li\u003e\n\u003cli\u003eBacklit digital display shows gas type and concentration; 4-20 mA output\u003c\/li\u003e\n\u003cli\u003e115\/220 VAC or 24 VDC operation\u003c\/li\u003e\n\u003cli\u003eCompact, weatherproof NEMA 4X enclosure; complies with lock-out\/tag-out standards; external reset switch\u003c\/li\u003e\n\u003cli\u003eShips with wall mounting kit\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 8.5″ 216 mm\u003cbr\u003eWidth 7.0″ 178 mm\u003cbr\u003eDepth 4.3″ 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eWall mounting grey polycarbonate with hinged cover.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit\u003cbr\u003eConnection\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\/4″ NPT conduit hubs, 2 provided.\u003cbr\u003e1 for sensor wiring\u003cbr\u003e1 for power \u0026amp; relay wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003cbr\u003eTermination\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eScrew type terminal block 14 gauge max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Power \u003c\/td\u003e\n\u003ctd\u003eUniversal 115 VAC \u0026amp; 220 VAC, or 24 VDC nominal, battery backup option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Controls \u003c\/td\u003e\n\u003ctd\u003e3 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eEnvironmental\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-20°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative\u003cbr\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 – 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003cbr\u003eRating\u003c\/td\u003e\n\u003ctd\u003eNEMA-4X enclosure, waterproof, chemical, and weather resistant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eInputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Wired\u003cbr\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eLEL\u003cbr\u003eOxygen\u003cbr\u003eCarbon Monoxide\u003cbr\u003eHydrogen Sulfide\u003cbr\u003eRemote amp not required for less than 500 feet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Sensors\u003c\/td\u003e\n\u003ctd\u003eAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI\/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Methods\u003c\/td\u003e\n\u003ctd\u003eDiffusion and sample draw heads available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eOutputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003e3 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarms and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003eSignal output, 4-20 mA (maximum load impedance 500 ohms), per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC (400 mA max) output provided to operate sample drawing adapters or other accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2 x 8 Alphanumeric display with backlighting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible\u003c\/td\u003e\n\u003ctd\u003eBuilt-in audible alarm, 94 dB, mounted on enclosure\u003cbr\u003eCoded output: pulsing = gas alarm, steady = fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual\u003c\/td\u003e\n\u003ctd\u003e3 LED’s on the front cover for alarm status indication, and malfunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e Partial List Of Detectable Gases\u003cbr\u003e\u003cem\u003eMany other gases or ranges available. Contact RKI for gases or ranges not listed.\u003c\/em\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) \u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArsine (AsH\u003csub\u003e3\u003c\/sub\u003e )\u003c\/td\u003e\n\u003ctd\u003e0 – 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoron Trichloride (BCl\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide (CO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide (ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Trifluoride (ClF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustibles\u003c\/td\u003e\n\u003ctd\u003e0 -100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiborane (B\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e6\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorine (F\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen (H\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Fluoride (HF)\u003c\/td\u003e\n\u003ctd\u003e0 – 9.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Sulfide (H\u003csub\u003e2\u003c\/sub\u003eS)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitric Oxide (NO)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Dioxide (NO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Trifluoride (NF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 25.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone (O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphine (PH\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilane (SiH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfur Dioxide (SO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEOS (Si(OC\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e5\u003c\/sub\u003e)\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 -15\/30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-2110RK-02\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39514545651747,"sku":"72-2110RK-02","price":2158.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Beacon-110-russmillsafety.com.png?v=1794189727"},{"product_id":"beacon-200-two-channel-wall-mount-controller","title":"Beacon 200 Two Channel Wall Mount Controller by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Beacon® 200 two-channel wall-mount controller (115–220 VAC, no sensor): a powerful, low-cost, microprocessor-controlled fixed system controller for two points of gas detection.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneous readout on 2 channels with backlit display of gas type and concentration\u003c\/li\u003e\n\u003cli\u003eTwo alarm levels per channel; discrete and common relays rated 10 A to drive most external alarms and horns\u003c\/li\u003e\n\u003cli\u003eConnects directly to RKI LEL, oxygen, H2S or CO sensors, or any 4-20 mA transmitter (2 or 3 wire, 24 VDC)\u003c\/li\u003e\n\u003cli\u003eSensors mount at the housing or wire remotely\u003c\/li\u003e\n\u003cli\u003e4-20 mA outputs\u003c\/li\u003e\n\u003cli\u003eNEMA 4X housing for corrosion resistance and weather-tight seal; complies with lock-out\/tag-out standards\u003c\/li\u003e\n\u003cli\u003eExternal reset switch silences alarm from outside the housing\u003c\/li\u003e\n\u003cli\u003eWall mounting kit included\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 10.5” 267 mm Width: 8.5” 216 mm Depth: 6.3” 158 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eWall mounting grey polycarbonate with hinged cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit Connection \u003c\/td\u003e\n\u003ctd\u003e3\/4” NPT conduit hubs, 3 provided. 2 for sensor wiring and 1 for power \u0026amp; relay wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Termination \u003c\/td\u003e\n\u003ctd\u003eScrew type terminal block, 14 gauge max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Controls \u003c\/td\u003e\n\u003ctd\u003e4 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eEnvironmental\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-10°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 – 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA-4X enclosure, waterproof, chemical, and weather resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eInputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Wired Sensors\u003c\/td\u003e\n\u003ctd\u003eLEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide Remote amp not required for less than 500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Sensors\u003c\/td\u003e\n\u003ctd\u003eAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI\/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Methods\u003c\/td\u003e\n\u003ctd\u003eDiffusion and sample draw heads available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eOutputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003e7 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarm levels per channel, plus 2 relays for common gas alarm and 1 common relay for malfunction. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003eSignal output, 4-20 mA (into 1000 ohms impedance maximum), per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC (350 mA max) output provided to operate sample drawing adapters or other accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eAlphanumeric display with backlighting. 20 characters per line; 4 lines each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible\u003c\/td\u003e\n\u003ctd\u003eBuilt-in audible alarm, 94 dB, mounted on enclosure Coded output: pulsing = gas alarm, steady = fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual\u003c\/td\u003e\n\u003ctd\u003e4 LED’s on the front cover for alarm status indication, pilot, and malfunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Expansion Cards \u003c\/td\u003e\n\u003ctd\u003eIndividual 4-20 mA (or 1 – 5 VDC) outputs Heavy duty relay card (4 each @ 30 amps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePower\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e110-240 VAC or 24 VDC standard. Battery backup option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e Partial List Of Detectable Gases \u003cem\u003eMany other gases or ranges available. Contact RKI for gases or ranges not listed.\u003c\/em\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) \u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArsine (AsH\u003csub\u003e3\u003c\/sub\u003e )\u003c\/td\u003e\n\u003ctd\u003e0 – 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoron Trichloride (BCl\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide (CO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide (ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Trifluoride (ClF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustibles\u003c\/td\u003e\n\u003ctd\u003e0 -100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiborane (B\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e6\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorine (F\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen (H\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Fluoride (HF)\u003c\/td\u003e\n\u003ctd\u003e0 – 9.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Sulfide (H\u003csub\u003e2\u003c\/sub\u003eS)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitric Oxide (NO)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Dioxide (NO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Trifluoride (NF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 25.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone (O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphine (PH\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilane (SiH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfur Dioxide (SO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEOS (Si(OC\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e5\u003c\/sub\u003e)\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 -15\/30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-2102RK\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39514570489891,"sku":"72-2102RK","price":3569.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Beacon-200-russmillsafety.com.png?v=1794189727"},{"product_id":"beacon-410a-four-channel-wall-mount-controller-by-rki-instruments","title":"Beacon 410A Four Channel Wall Mount Controller by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Beacon 410A four-channel wall-mount controller (72-2104A, no sensor): highly configurable, microprocessor-based and easy to use.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSimultaneously displays gas type, readings and status for 4 channels on an OLED display\u003c\/li\u003e\n\u003cli\u003eMonitors any combination of direct-connect LEL, O2, CO2 and toxic sensors, plus any 4-20 mA transmitter (2 or 3 wire)\u003c\/li\u003e\n\u003cli\u003eUp to 3 configurable alarm points and up to 3 alarm relays per channel; built-in trouble alarm with relay\u003c\/li\u003e\n\u003cli\u003eSilenceable audible alarm; alarm reset switch\u003c\/li\u003e\n\u003cli\u003e4-20 mA output per channel; Modbus digital output standard\u003c\/li\u003e\n\u003cli\u003eMin-Max feature retains high and low peaks\u003c\/li\u003e\n\u003cli\u003e115\/220 VAC or external 24 VDC; optional battery backup and high-visibility strobe\u003c\/li\u003e\n\u003cli\u003eAll features built in: no add-on cards needed\u003c\/li\u003e\n\u003cli\u003eRFI\/EMI resistant; weather and corrosion resistant NEMA 4X enclosure\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 12.5” Width 11” Depth 6.4”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X non-metallic for indoor and outdoor locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit Connection \u003c\/td\u003e\n\u003ctd\u003e3\/4” NPT conduit hubs, 4 provided, for sensor, power, \u0026amp; relay wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Termination \u003c\/td\u003e\n\u003ctd\u003eScrew type terminal block, 14 gauge max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Power \u003c\/td\u003e\n\u003ctd\u003e115 VAC \u0026amp; 220 VAC, or 24 VDC nominal, battery backup option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Controls \u003c\/td\u003e\n\u003ctd\u003eDisplay PCB Control Switches:   \u003cul\u003e\n\u003cli\u003eUP\/YES push button switch\u003c\/li\u003e\n\u003cli\u003eDOWN\/NO push button switch\u003c\/li\u003e\n\u003cli\u003eESCAPE push button switch\u003c\/li\u003e\n\u003cli\u003eENTER push button switch\u003c\/li\u003e\n\u003cli\u003eExternal reset switch\u003c\/li\u003e\n\u003cli\u003eOn\/Off toggle switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eEnvironmental\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-20°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e0 – 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA-4X enclosure, chemical and weather resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eInputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Wired Sensors\u003c\/td\u003e\n\u003ctd\u003eLEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide, and Carbon Dioxide. Remote amp not required for less than 500 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Sensors\u003c\/td\u003e\n\u003ctd\u003eAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI\/Riken sensors are available with 4-20 mA signals. Wiring distances up to 8,000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Methods\u003c\/td\u003e\n\u003ctd\u003eDiffusion and sample draw heads available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eOutputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003eTwo flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. 10A contact rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003eSignal output, 4-20 mA (maximum load impedance 500 ohms), per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003ctd\u003eModbus format RS-485 serial output of all channel data, including gas reading and alarm status.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eFour line OLED display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible\u003c\/td\u003e\n\u003ctd\u003eBuilt-in audible alarm, 94 dB, mounted on enclosure Coded output: pulsing = gas alarm, steady = fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual\u003c\/td\u003e\n\u003ctd\u003e1. Alarm LEDs (on Display PCB)   \u003cul\u003e\n\u003cli\u003eAlarm 1, yellow\u003c\/li\u003e\n\u003cli\u003eAlarm 2, orange\u003c\/li\u003e\n\u003cli\u003eAlarm 3, red\u003c\/li\u003e\n\u003cli\u003eFail, yellow\u003c\/li\u003e\n\u003c\/ul\u003e 2. Green Pilot LED to indicate AC power connected (on Display PCB) 3. An optional 24 VDC NEMA 4X strobe mounted to top of case. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e Partial List Of Detectable Gases \u003cem\u003eMany other gases or ranges available. Contact RKI for gases or ranges not listed.\u003c\/em\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) \u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArsine (AsH\u003csub\u003e3\u003c\/sub\u003e )\u003c\/td\u003e\n\u003ctd\u003e0 – 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoron Trichloride (BCl\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide (CO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide (ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Trifluoride (ClF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustibles\u003c\/td\u003e\n\u003ctd\u003e0 -100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiborane (B\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e6\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorine (F\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen (H\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Fluoride (HF)\u003c\/td\u003e\n\u003ctd\u003e0 – 9.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Sulfide (H\u003csub\u003e2\u003c\/sub\u003eS)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitric Oxide (NO)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Dioxide (NO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Trifluoride (NF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 25.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone (O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphine (PH\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilane (SiH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfur Dioxide (SO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEOS (Si(OC\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e5\u003c\/sub\u003e)\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 -15\/30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-2104A\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39514652442659,"sku":"72-2104A","price":4622.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Beacon-410A-russmillsafety.com.png?v=1794189726"},{"product_id":"beacon-800-eight-channel-wall-mount-controller-by-rki-instruments","title":"Beacon 800 Eight Channel Wall Mount Controller by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Beacon® 800 eight-channel wall-mount controller (72-2108RK): versatile, low-cost fixed system controller for one to eight points of gas detection.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccepts up to 8 separate 4-20 mA sensor transmitters (2 or 3 wire)\u003c\/li\u003e\n\u003cli\u003eTwo large backlit digital displays show gas type and concentration for all 8 channels simultaneously\u003c\/li\u003e\n\u003cli\u003eTwo programmable alarm levels per channel; audible alarm with reset button; common alarm and fail relays\u003c\/li\u003e\n\u003cli\u003e3 A form C relays wire directly to horns, buzzers or lights, no external relays needed\u003c\/li\u003e\n\u003cli\u003e85–264 VAC or 24 VDC operation; long-life sensors (2+ years typical)\u003c\/li\u003e\n\u003cli\u003eCompact, weatherproof NEMA 4X enclosure; complies with lock-out\/tag-out standards; external reset switch\u003c\/li\u003e\n\u003cli\u003eBottom-mounted wiring hubs; complete with wall mount installation kit\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 12.5″ 318 mm\u003cbr\u003eWidth 11.0″ 279 mm\u003cbr\u003eDepth 6.4″ 163 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eWall mounting grey polycarbonate with hinged cover.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit\u003cbr\u003eConnection\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\/4″ NPT conduit hubs, 4 provided for sensors, power and relay wiring.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003cbr\u003eTermination\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eScrew type terminal block, 14 gauge max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eEnvironmental\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-10°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative\u003cbr\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 – 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003cbr\u003eRating\u003c\/td\u003e\n\u003ctd\u003eNEMA-4X enclosure, waterproof, chemical, and weather resistant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eInputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003eAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI sensors are available with4-20 mA signals. Wiring distances up to 8,000 feet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eOutputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003e2 relays per channel 10 amp rating, SPDT isolated contacts.   1 set of common relays: \u003cul\u003e\n\u003cli type=\"square\"\u003e2 for gas alarm levels\u003c\/li\u003e\n\u003cli type=\"square\"\u003e1 for malfunction\u003c\/li\u003e\n\u003c\/ul\u003e Relays fully programmable for: \u003cul\u003e\n\u003cli\u003eIncreasing or decreasing alarms\u003c\/li\u003e\n\u003cli\u003eLatching or self reset\u003c\/li\u003e\n\u003cli\u003eNormally energized or normally de-energized\u003c\/li\u003e\n\u003cli\u003eTime delay for alarm on and alarm off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2 alphanumeric displays with backlighting. 16 characters per line; 4 lines each. All 8 channels continuously displayed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible\u003c\/td\u003e\n\u003ctd\u003eBuilt-in audible alarm, 94 dB steady tone, mounted on enclosure.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual\u003c\/td\u003e\n\u003ctd\u003e4 visual LED alarms on front cover for alarm indications, pilot, and malfunction.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional\u003cbr\u003eExpansion Cards\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eIndividual 4-20 mA (or 1 – 5 VDC) outputs\u003cbr\u003eHeavy duty relay card (4 each @ 30 amps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePower\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC or 24 VDC standard\u003cbr\u003eBattery backup option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eApprovals\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA Certified to CSA C22.2 No. 1010 and ANSI\/ISA S82.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year materials and workmanship.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e Partial List Of Detectable Gases\u003cbr\u003e\u003cem\u003eMany other gases or ranges available. Contact RKI for gases or ranges not listed.\u003c\/em\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) \u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArsine (AsH\u003csub\u003e3\u003c\/sub\u003e )\u003c\/td\u003e\n\u003ctd\u003e0 – 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoron Trichloride (BCl\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide (CO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide (ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Trifluoride (ClF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustibles\u003c\/td\u003e\n\u003ctd\u003e0 -100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiborane (B\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e6\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorine (F\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen (H\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Fluoride (HF)\u003c\/td\u003e\n\u003ctd\u003e0 – 9.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Sulfide (H\u003csub\u003e2\u003c\/sub\u003eS)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitric Oxide (NO)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Dioxide (NO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Trifluoride (NF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 25.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone (O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphine (PH\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilane (SiH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfur Dioxide (SO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEOS (Si(OC\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e5\u003c\/sub\u003e)\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 -15\/30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-2108RK\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39514693369891,"sku":"72-2108RK","price":4833.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Beacon-800-russmillsafety.com.png?v=1794189726"},{"product_id":"direct-connect-sensors-fixed-gas-detection-by-rki-instruments","title":"Direct Connect Sensors (O2, H2S, CO) by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Direct Connect series fixed gas sensors (O2, H2S, CO): highly reliable, very cost-effective detection of common gas hazards.\u003c\/p\u003e\n\u003cp\u003eGas options: Hydrogen Sulfide (H2S), Oxygen (O2), Carbon Monoxide (CO). Styles: Add J-Box, Sensor.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries available for LEL, H2-specific LEL, LEL IR, oxygen, H2S, CO, CO2 and a variety of toxic gases\u003c\/li\u003e\n\u003cli\u003eLEL, H2, oxygen, H2S, CO2 and CO sensors are explosion-proof with flame arrestors, approved for Class 1, Div. 1, Groups B, C, D; optional non-explosion-proof version for oxygen, H2S, CO and CO2 (Class 1, Div. 2)\u003c\/li\u003e\n\u003cli\u003eMount directly to controllers as a stand-alone system, or to explosion-proof junction boxes for remote detection\u003c\/li\u003e\n\u003cli\u003eToxic sensors are electrochemical plug-in types with tool-free field replacement\u003c\/li\u003e\n\u003cli\u003eIndoor or outdoor use; patented water-repellent flame arrestor coating; splash guards available\u003c\/li\u003e\n\u003cli\u003eOptional stainless steel junction box for corrosive environments\u003c\/li\u003e\n\u003cli\u003eDesigned to interface with RKI Beacon 110, 200 and 410A controllers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct image\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\" alt=\"S2 toxic sensor\" width=\"120\" height=\"246\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003e\u003ch3\u003eExplosion Proof Class I, Div. 2 , Groups B, C, D\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e LEL\u003cbr\u003eGeneral Purpose \u003c\/td\u003e\n\u003ctd\u003e LEL \u003cbr\u003eH2 Specific \u003c\/td\u003e\n\u003ctd\u003e O2\u003cbr\u003eOxygen \u003c\/td\u003e\n\u003ctd\u003e H2S\u003cbr\u003eHydrogen Sulfide \u003c\/td\u003e\n\u003ctd\u003e CO\u003cbr\u003eCarbon Monoxide \u003c\/td\u003e\n\u003ctd\u003e CH4\u003cbr\u003eMethane\u003cbr\u003eIR \u003c\/td\u003e\n\u003ctd\u003e HC Hydrocarbons\u003cbr\u003eIR \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e CO2\u003cbr\u003eCarbon Dioxide\u003cbr\u003eIR \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSensor\u003cbr\u003eWith J-Box\u003c\/td\u003e\n\u003ctd\u003e61-1000RK (UL)\u003c\/td\u003e\n\u003ctd\u003e61-1001RK (UL)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2515RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2427RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2437RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e61-1003RK-CH4\u003cbr\u003e61-1006RK-CH4\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e61-1003RK-HC\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003e61-1004RK-02\u003cbr\u003e61-1004RK-03\u003cbr\u003e61-1004RK-05\u003cbr\u003e61-1004RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e61-1000RK-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003e61-1001RK-05 (CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCatalytic\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003cbr\u003eOnly\u003c\/td\u003e\n\u003ctd\u003e61-0140RK (UL)\u003cbr\u003e61-0140RK-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003eLEL H2 – NC-6205-01 (UL)\u003cbr\u003eNC-6205-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003e65-2514RK\u003c\/td\u003e\n\u003ctd\u003e65-2428\u003c\/td\u003e\n\u003ctd\u003e65-2438\u003c\/td\u003e\n\u003ctd\u003e61-0190RK-CH4\u003cbr\u003e61-0192RK-CH4\u003c\/td\u003e\n\u003ctd\u003e61-0190RK-HC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e61-0191RK-02\u003cbr\u003e61-0191RK-03\u003cbr\u003e61-0191RK-05\u003cbr\u003e61-0191RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003cbr\u003e0-100% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e-02\u003cbr\u003e-03\u003cbr\u003e-05\u003cbr\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0 – 5000ppm\u003cbr\u003e0 – 5.0%Vol.\u003cbr\u003e0 – 50%Vol.\u003cbr\u003e0 – 100%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% of full scale\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse\u003cbr\u003eTime (T-90)\u003c\/td\u003e\n\u003ctd\u003eLEL – 30 Seconds\u003c\/td\u003e\n\u003ctd\u003eLEL H2 – 20 Seconds\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003c\/td\u003e\n\u003ctd\u003e60 Seconds\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e+\/- 5% of full scale (0.5% volume for oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Life   Expectancy \u003c\/td\u003e\n\u003ctd\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 years plus with normal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eIndoor or outdoor. Explosion proof for Class I, Groups B, C, and D atmospheres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°F to 167°F\u003cbr\u003e-40°C to 75°C\u003c\/td\u003e\n\u003ctd\u003e-4°F to 113°F\u003cbr\u003e-20°C to 45°C\u003c\/td\u003e\n\u003ctd\u003e-40°F to 104°F\u003cbr\u003e-40°C to 40°C\u003c\/td\u003e\n\u003ctd\u003e23°F to 104°F\u003cbr\u003e-5°C to 40°C\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40°F to 122°F\u003cbr\u003e-40°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e0 – 99% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCast aluminum, explosion-proof. Optional stainless steel J-box available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eStainless steel, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003e61-1000RK UL\u003c\/td\u003e\n\u003ctd\u003e61-1001RK UL\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003eCSA NRTL\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eC UL US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e61-1000RK-05 CSA\u003c\/td\u003e\n\u003ctd\u003e61-1001RK-05 CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e\u003ch3\u003eToxic Gas Transmitters Class I, Div. 2\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eO2\u003cbr\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003eH2S\u003cbr\u003eHydrogen Sulfide\u003c\/td\u003e\n\u003ctd\u003eCO\u003cbr\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003eCO2\u003cbr\u003eCarbon Dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor With J-Box\u003c\/td\u003e\n\u003ctd\u003e65-2497RK\u003cbr\u003e*65-2502RK\u003c\/td\u003e\n\u003ctd\u003e65-2498RK\u003c\/td\u003e\n\u003ctd\u003e65-2499RK\u003c\/td\u003e\n\u003ctd\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e61-1007RK-02\u003cbr\u003e61-1007RK-03\u003cbr\u003e61-1007RK-05\u003cbr\u003e61-1007RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Only\u003c\/td\u003e\n\u003ctd\u003e65-2494RK   *65-2510RK \u003c\/td\u003e\n\u003ctd\u003e65-2495RK\u003c\/td\u003e\n\u003ctd\u003e65-2496RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e61-0198RK-02\u003cbr\u003e61-0198RK-03\u003cbr\u003e61-0198RK-05\u003cbr\u003e61-0198RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd\u003e0 – 5000ppm\u003cbr\u003e0 – 5.0%Vol.\u003cbr\u003e0 – 50%Vol.\u003cbr\u003e0 – 100%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd\u003e20 seconds or less\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e35 seconds or less\u003c\/td\u003e\n\u003ctd\u003e60 seconds or less\u003c\/td\u003e\n\u003ctd\u003e30 seconds or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e+\/- 5% of full scale (0.5% volume for oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e2 years withnormal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e5 years plus with\u003cbr\u003enormal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIndoor or outdoor, Class I, Div. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-4°F to 122°F\u003cbr\u003e-20°C to 50°C\u003c\/td\u003e\n\u003ctd\u003e14°F to 104°F\u003cbr\u003e-10°C to 40°C\u003c\/td\u003e\n\u003ctd\u003e-40°F to 122°F\u003cbr\u003e-40°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0 – 99% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCast aluminum, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"17\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\" alt=\"S2 toxic sensor\" nitro-lazy-empty=\"\" nitro-lazy-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e\u003ch3\u003eToxic Direct Connect Sensor Ordering Information\u003c\/h3\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number With J-Box\u003c\/td\u003e\n\u003ctd\u003ePart Number Without J-box\u003c\/td\u003e\n\u003ctd\u003eGas\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-NH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-NH3\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)*\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-75\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-75\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-1\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-1\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-2\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-2\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 200 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-5\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-5\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 500 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-AsH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-AsH3\u003c\/td\u003e\n\u003ctd\u003eArsine (AsH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CL2-3\u003c\/td\u003e\n\u003ctd\u003e65-2302-CL2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CL2-10\u003c\/td\u003e\n\u003ctd\u003e65-2302-CL2-10\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 10.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-1\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-1\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-3\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-5\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-5\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 5.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-HCN\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-HCN\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-PH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-PH3\u003c\/td\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-SO2\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-SO2\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide (SO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e* Sensor being phased out, use CT-7 type when possible.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003ch3\u003eDirect Connect Wiring Matrix\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSensor\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eNumber of Wires to Controller\u003c\/td\u003e\n\u003ctd\u003eMaximum Distance to Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e18 AWG wire min.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL \/ CO2 \/ IR\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2S\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdd J-Box \/ Hydrogen Sulfide (H2S) — SKU: 65-2427RK-05\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ Oxygen (O2) — SKU: 65-2515RK\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ Carbon Monoxide (CO) — SKU: 65-2437RK-05\u003c\/li\u003e\n\u003cli\u003eSensor \/ Hydrogen Sulfide (H2S) — SKU: 65-2428\u003c\/li\u003e\n\u003cli\u003eSensor \/ Oxygen (O2) — SKU: 65-2514RK\u003c\/li\u003e\n\u003cli\u003eSensor \/ Carbon Monoxide (CO) — SKU: 65-2438\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"Add J-Box \/ Hydrogen Sulfide (H2S)","offer_id":39514710278179,"sku":"65-2427RK-05","price":1042.5,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ Oxygen (O2)","offer_id":39514710310947,"sku":"65-2515RK","price":1042.5,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ Carbon Monoxide (CO)","offer_id":39514710343715,"sku":"65-2437RK-05","price":1042.5,"currency_code":"USD","in_stock":true},{"title":"Sensor \/ Hydrogen Sulfide (H2S)","offer_id":39514710376483,"sku":"65-2428","price":842.4,"currency_code":"USD","in_stock":true},{"title":"Sensor \/ Oxygen (O2)","offer_id":39514710409251,"sku":"65-2514RK","price":758.2,"currency_code":"USD","in_stock":true},{"title":"Sensor \/ Carbon Monoxide (CO)","offer_id":39514710442019,"sku":"65-2438","price":842.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Direct-Connect-Sensors-O2-H2S-CO-russmillsafety.com.png?v=1637610240"},{"product_id":"direct-connect-sensors-lel-ch4-hc-co2-by-rki-instruments","title":"Direct Connect Sensors (LEL, CH4, HC, CO2) by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Direct Connect series fixed gas sensors: highly reliable, very cost-effective detection of common gas hazards.\u003c\/p\u003e\n\u003cp\u003eGas options: LEL, CH4, HC, CO2 (0-5.0%), CO2 (0-50%), CO2 (0-100%), CO2 (0-5000 ppm). Styles: Add J-Box, Sensor only.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable for LEL, H2-specific LEL, LEL IR, oxygen, H2S, CO, CO2 and a variety of toxic gases\u003c\/li\u003e\n\u003cli\u003eLEL, H2, oxygen, H2S, CO2 and CO sensors are explosion-proof with flame arrestors, approved for Class 1, Div. 1, Groups B, C, D; optional non-explosion-proof version for oxygen, H2S, CO and CO2 (Class 1, Div. 2)\u003c\/li\u003e\n\u003cli\u003eMount directly to controllers as a stand-alone system, or to explosion-proof junction boxes for remote detection\u003c\/li\u003e\n\u003cli\u003eToxic sensors (NH3, AsH3, Cl2, ClO2, HCN, PH3, SO2) are electrochemical plug-in types with high specificity, fast response and long life; tool-free field replacement; for Class I, Div. 2\u003c\/li\u003e\n\u003cli\u003eIndoor or outdoor use; patented water-repellent flame arrestor coating; splash guards available for very wet environments\u003c\/li\u003e\n\u003cli\u003eOptional stainless steel junction box for corrosive environments\u003c\/li\u003e\n\u003cli\u003eDesigned to interface with RKI Beacon 110, 200 and 410A controllers\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct image\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\" alt=\"S2 toxic sensor\" width=\"120\" height=\"246\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003e\u003ch3\u003eExplosion Proof Class I, Div. 2 , Groups B, C, D\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e LEL\u003cbr\u003eGeneral Purpose \u003c\/td\u003e\n\u003ctd\u003e LEL \u003cbr\u003eH2 Specific \u003c\/td\u003e\n\u003ctd\u003e O2\u003cbr\u003eOxygen \u003c\/td\u003e\n\u003ctd\u003e H2S\u003cbr\u003eHydrogen Sulfide \u003c\/td\u003e\n\u003ctd\u003e CO\u003cbr\u003eCarbon Monoxide \u003c\/td\u003e\n\u003ctd\u003e CH4\u003cbr\u003eMethane\u003cbr\u003eIR \u003c\/td\u003e\n\u003ctd\u003e HC Hydrocarbons\u003cbr\u003eIR \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e CO2\u003cbr\u003eCarbon Dioxide\u003cbr\u003eIR \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSensor\u003cbr\u003eWith J-Box\u003c\/td\u003e\n\u003ctd\u003e61-1000RK (UL)\u003c\/td\u003e\n\u003ctd\u003e61-1001RK (UL)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2515RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2427RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2437RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e61-1003RK-CH4\u003cbr\u003e61-1006RK-CH4\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e61-1003RK-HC\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003e61-1004RK-02\u003cbr\u003e61-1004RK-03\u003cbr\u003e61-1004RK-05\u003cbr\u003e61-1004RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e61-1000RK-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003e61-1001RK-05 (CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCatalytic\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003cbr\u003eOnly\u003c\/td\u003e\n\u003ctd\u003e61-0140RK (UL)\u003cbr\u003e61-0140RK-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003eLEL H2 – NC-6205-01 (UL)\u003cbr\u003eNC-6205-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003e65-2514RK\u003c\/td\u003e\n\u003ctd\u003e65-2428\u003c\/td\u003e\n\u003ctd\u003e65-2438\u003c\/td\u003e\n\u003ctd\u003e61-0190RK-CH4\u003cbr\u003e61-0192RK-CH4\u003c\/td\u003e\n\u003ctd\u003e61-0190RK-HC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e61-0191RK-02\u003cbr\u003e61-0191RK-03\u003cbr\u003e61-0191RK-05\u003cbr\u003e61-0191RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003cbr\u003e0-100% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e-02\u003cbr\u003e-03\u003cbr\u003e-05\u003cbr\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0 – 5000ppm\u003cbr\u003e0 – 5.0%Vol.\u003cbr\u003e0 – 50%Vol.\u003cbr\u003e0 – 100%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% of full scale\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse\u003cbr\u003eTime (T-90)\u003c\/td\u003e\n\u003ctd\u003eLEL – 30 Seconds\u003c\/td\u003e\n\u003ctd\u003eLEL H2 – 20 Seconds\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003c\/td\u003e\n\u003ctd\u003e60 Seconds\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e+\/- 5% of full scale (0.5% volume for oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Life   Expectancy \u003c\/td\u003e\n\u003ctd\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 years plus with normal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eIndoor or outdoor. Explosion proof for Class I, Groups B, C, and D atmospheres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°F to 167°F\u003cbr\u003e-40°C to 75°C\u003c\/td\u003e\n\u003ctd\u003e-4°F to 113°F\u003cbr\u003e-20°C to 45°C\u003c\/td\u003e\n\u003ctd\u003e-40°F to 104°F\u003cbr\u003e-40°C to 40°C\u003c\/td\u003e\n\u003ctd\u003e23°F to 104°F\u003cbr\u003e-5°C to 40°C\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40°F to 122°F\u003cbr\u003e-40°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e0 – 99% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCast aluminum, explosion-proof. Optional stainless steel J-box available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eStainless steel, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003e61-1000RK UL\u003c\/td\u003e\n\u003ctd\u003e61-1001RK UL\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003eCSA NRTL\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eC UL US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e61-1000RK-05 CSA\u003c\/td\u003e\n\u003ctd\u003e61-1001RK-05 CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e\u003ch3\u003eToxic Gas Transmitters Class I, Div. 2\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eO2\u003cbr\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003eH2S\u003cbr\u003eHydrogen Sulfide\u003c\/td\u003e\n\u003ctd\u003eCO\u003cbr\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003eCO2\u003cbr\u003eCarbon Dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor With J-Box\u003c\/td\u003e\n\u003ctd\u003e65-2497RK\u003cbr\u003e*65-2502RK\u003c\/td\u003e\n\u003ctd\u003e65-2498RK\u003c\/td\u003e\n\u003ctd\u003e65-2499RK\u003c\/td\u003e\n\u003ctd\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e61-1007RK-02\u003cbr\u003e61-1007RK-03\u003cbr\u003e61-1007RK-05\u003cbr\u003e61-1007RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Only\u003c\/td\u003e\n\u003ctd\u003e65-2494RK   *65-2510RK \u003c\/td\u003e\n\u003ctd\u003e65-2495RK\u003c\/td\u003e\n\u003ctd\u003e65-2496RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e61-0198RK-02\u003cbr\u003e61-0198RK-03\u003cbr\u003e61-0198RK-05\u003cbr\u003e61-0198RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd\u003e0 – 5000ppm\u003cbr\u003e0 – 5.0%Vol.\u003cbr\u003e0 – 50%Vol.\u003cbr\u003e0 – 100%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd\u003e20 seconds or less\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e35 seconds or less\u003c\/td\u003e\n\u003ctd\u003e60 seconds or less\u003c\/td\u003e\n\u003ctd\u003e30 seconds or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e+\/- 5% of full scale (0.5% volume for oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e2 years withnormal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e5 years plus with\u003cbr\u003enormal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIndoor or outdoor, Class I, Div. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-4°F to 122°F\u003cbr\u003e-20°C to 50°C\u003c\/td\u003e\n\u003ctd\u003e14°F to 104°F\u003cbr\u003e-10°C to 40°C\u003c\/td\u003e\n\u003ctd\u003e-40°F to 122°F\u003cbr\u003e-40°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0 – 99% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCast aluminum, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"17\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\" alt=\"S2 toxic sensor\" nitro-lazy-empty=\"\" nitro-lazy-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e\u003ch3\u003eToxic Direct Connect Sensor Ordering Information\u003c\/h3\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number With J-Box\u003c\/td\u003e\n\u003ctd\u003ePart Number Without J-box\u003c\/td\u003e\n\u003ctd\u003eGas\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-NH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-NH3\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)*\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-75\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-75\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-1\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-1\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-2\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-2\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 200 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-5\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-5\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 500 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-AsH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-AsH3\u003c\/td\u003e\n\u003ctd\u003eArsine (AsH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CL2-3\u003c\/td\u003e\n\u003ctd\u003e65-2302-CL2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CL2-10\u003c\/td\u003e\n\u003ctd\u003e65-2302-CL2-10\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 10.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-1\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-1\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-3\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-5\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-5\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 5.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-HCN\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-HCN\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-PH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-PH3\u003c\/td\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-SO2\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-SO2\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide (SO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e* Sensor being phased out, use CT-7 type when possible.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003ch3\u003eDirect Connect Wiring Matrix\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSensor\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eNumber of Wires to Controller\u003c\/td\u003e\n\u003ctd\u003eMaximum Distance to Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e18 AWG wire min.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL \/ CO2 \/ IR\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2S\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdd J-Box \/ LEL — SKU: 61-1000RK\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ CH4 — SKU: 61-1003RK-CH4\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ HC — SKU: 61-1003RK-HC\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ CO2 (0-5.0%) — SKU: 61-1004RK-03\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ CO2 (0-50%) — SKU: 61-1004RK-05\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ CO2 (0-100%) — SKU: 61-1004RK-10\u003c\/li\u003e\n\u003cli\u003eAdd J-Box \/ CO2 (0-5000 ppm) — SKU: 61-1004RK-02\u003c\/li\u003e\n\u003cli\u003eSensor only \/ LEL — SKU: 61-0140RK\u003c\/li\u003e\n\u003cli\u003eSensor only \/ CH4 — SKU: 61-0190RK-CH4\u003c\/li\u003e\n\u003cli\u003eSensor only \/ HC — SKU: 61-0190RK-HC\u003c\/li\u003e\n\u003cli\u003eSensor only \/ CO2 (0-5.0%) — SKU: 61-0191RK-03\u003c\/li\u003e\n\u003cli\u003eSensor only \/ CO2 (0-50%) — SKU: 61-0191RK-05\u003c\/li\u003e\n\u003cli\u003eSensor only \/ CO2 (0-100%) — SKU: 61-0191RK-10\u003c\/li\u003e\n\u003cli\u003eSensor only \/ CO2 (0-5000 ppm) — SKU: 61-0191RK-02\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"Add J-Box \/ LEL","offer_id":39515558215715,"sku":"61-1000RK","price":737.1,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ CH4","offer_id":39515558248483,"sku":"61-1003RK-CH4","price":1684.8,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ HC","offer_id":39515558281251,"sku":"61-1003RK-HC","price":1684.8,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ CO2 (0-5.0%)","offer_id":39515558314019,"sku":"61-1004RK-03","price":1684.8,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ CO2 (0-50%)","offer_id":39515558346787,"sku":"61-1004RK-05","price":1684.8,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ CO2 (0-100%)","offer_id":39515558379555,"sku":"61-1004RK-10","price":1684.8,"currency_code":"USD","in_stock":true},{"title":"Add J-Box \/ CO2 (0-5000 ppm)","offer_id":39515558412323,"sku":"61-1004RK-02","price":1684.8,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ LEL","offer_id":39515558445091,"sku":"61-0140RK","price":526.5,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ CH4","offer_id":39515558477859,"sku":"61-0190RK-CH4","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ HC","offer_id":39515558510627,"sku":"61-0190RK-HC","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ CO2 (0-5.0%)","offer_id":39515558543395,"sku":"61-0191RK-03","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ CO2 (0-50%)","offer_id":39515558576163,"sku":"61-0191RK-05","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ CO2 (0-100%)","offer_id":39515558608931,"sku":"61-0191RK-10","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"Sensor only \/ CO2 (0-5000 ppm)","offer_id":39515558641699,"sku":"61-0191RK-02","price":1474.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Direct-Connect-Sensors-by-RKI-Instruments-russmillsafety.com.png?v=1637678934"},{"product_id":"direct-connect-sensor-lel-h2-specific-by-rki-instruments","title":"Direct Connect Sensor (LEL, H2 Specific) by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Direct Connect series fixed gas sensor (LEL, H2 specific): highly reliable, very cost-effective detection of common gas hazards.\u003c\/p\u003e\n\u003cp\u003eStyles: Add J-Box, Sensor Only.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries available for LEL, H2-specific LEL, LEL IR, oxygen, H2S, CO, CO2 and a variety of toxic gases\u003c\/li\u003e\n\u003cli\u003eLEL, H2, oxygen, H2S, CO2 and CO sensors are explosion-proof with flame arrestors, approved for Class 1, Div. 1, Groups B, C, D; optional non-explosion-proof version for oxygen, H2S, CO and CO2 (Class 1, Div. 2)\u003c\/li\u003e\n\u003cli\u003eMount directly to controllers as a stand-alone system, or to explosion-proof junction boxes for remote detection\u003c\/li\u003e\n\u003cli\u003eToxic sensors (NH3, AsH3, Cl2, ClO2, HCN, PH3, SO2) are electrochemical plug-in types with tool-free field replacement, for Class I, Div. 2\u003c\/li\u003e\n\u003cli\u003eIndoor or outdoor use; patented water-repellent flame arrestor coating; splash guards available\u003c\/li\u003e\n\u003cli\u003eOptional stainless steel junction box for corrosive environments\u003c\/li\u003e\n\u003cli\u003eDesigned to interface with RKI Beacon 110, 200 and 410A controllers\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct image\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\" alt=\"S2 toxic sensor\" width=\"120\" height=\"246\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003e\u003ch3\u003eExplosion Proof Class I, Div. 2 , Groups B, C, D\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e LEL\u003cbr\u003eGeneral Purpose \u003c\/td\u003e\n\u003ctd\u003e LEL \u003cbr\u003eH2 Specific \u003c\/td\u003e\n\u003ctd\u003e O2\u003cbr\u003eOxygen \u003c\/td\u003e\n\u003ctd\u003e H2S\u003cbr\u003eHydrogen Sulfide \u003c\/td\u003e\n\u003ctd\u003e CO\u003cbr\u003eCarbon Monoxide \u003c\/td\u003e\n\u003ctd\u003e CH4\u003cbr\u003eMethane\u003cbr\u003eIR \u003c\/td\u003e\n\u003ctd\u003e HC Hydrocarbons\u003cbr\u003eIR \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e CO2\u003cbr\u003eCarbon Dioxide\u003cbr\u003eIR \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSensor\u003cbr\u003eWith J-Box\u003c\/td\u003e\n\u003ctd\u003e61-1000RK (UL)\u003c\/td\u003e\n\u003ctd\u003e61-1001RK (UL)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2515RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2427RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2437RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e61-1003RK-CH4\u003cbr\u003e61-1006RK-CH4\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e61-1003RK-HC\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003e61-1004RK-02\u003cbr\u003e61-1004RK-03\u003cbr\u003e61-1004RK-05\u003cbr\u003e61-1004RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e61-1000RK-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003e61-1001RK-05 (CSA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCatalytic\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003cbr\u003eOnly\u003c\/td\u003e\n\u003ctd\u003e61-0140RK (UL)\u003cbr\u003e61-0140RK-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003eLEL H2 – NC-6205-01 (UL)\u003cbr\u003eNC-6205-05 (CSA)\u003c\/td\u003e\n\u003ctd\u003e65-2514RK\u003c\/td\u003e\n\u003ctd\u003e65-2428\u003c\/td\u003e\n\u003ctd\u003e65-2438\u003c\/td\u003e\n\u003ctd\u003e61-0190RK-CH4\u003cbr\u003e61-0192RK-CH4\u003c\/td\u003e\n\u003ctd\u003e61-0190RK-HC\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e61-0191RK-02\u003cbr\u003e61-0191RK-03\u003cbr\u003e61-0191RK-05\u003cbr\u003e61-0191RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003cbr\u003e0-100% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100% LEL\u003c\/td\u003e\n\u003ctd\u003e-02\u003cbr\u003e-03\u003cbr\u003e-05\u003cbr\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0 – 5000ppm\u003cbr\u003e0 – 5.0%Vol.\u003cbr\u003e0 – 50%Vol.\u003cbr\u003e0 – 100%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2% of full scale\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse\u003cbr\u003eTime (T-90)\u003c\/td\u003e\n\u003ctd\u003eLEL – 30 Seconds\u003c\/td\u003e\n\u003ctd\u003eLEL H2 – 20 Seconds\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003c\/td\u003e\n\u003ctd\u003e60 Seconds\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003ctd\u003e30 Seconds\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e+\/- 5% of full scale (0.5% volume for oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Life   Expectancy \u003c\/td\u003e\n\u003ctd\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 years plus with normal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eIndoor or outdoor. Explosion proof for Class I, Groups B, C, and D atmospheres.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°F to 167°F\u003cbr\u003e-40°C to 75°C\u003c\/td\u003e\n\u003ctd\u003e-4°F to 113°F\u003cbr\u003e-20°C to 45°C\u003c\/td\u003e\n\u003ctd\u003e-40°F to 104°F\u003cbr\u003e-40°C to 40°C\u003c\/td\u003e\n\u003ctd\u003e23°F to 104°F\u003cbr\u003e-5°C to 40°C\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40°F to 122°F\u003cbr\u003e-40°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e0 – 99% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCast aluminum, explosion-proof. Optional stainless steel J-box available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eStainless steel, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003e61-1000RK UL\u003c\/td\u003e\n\u003ctd\u003e61-1001RK UL\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003eCSA NRTL\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eC UL US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e61-1000RK-05 CSA\u003c\/td\u003e\n\u003ctd\u003e61-1001RK-05 CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e\u003ch3\u003eToxic Gas Transmitters Class I, Div. 2\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eO2\u003cbr\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003eH2S\u003cbr\u003eHydrogen Sulfide\u003c\/td\u003e\n\u003ctd\u003eCO\u003cbr\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003eCO2\u003cbr\u003eCarbon Dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor With J-Box\u003c\/td\u003e\n\u003ctd\u003e65-2497RK\u003cbr\u003e*65-2502RK\u003c\/td\u003e\n\u003ctd\u003e65-2498RK\u003c\/td\u003e\n\u003ctd\u003e65-2499RK\u003c\/td\u003e\n\u003ctd\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e61-1007RK-02\u003cbr\u003e61-1007RK-03\u003cbr\u003e61-1007RK-05\u003cbr\u003e61-1007RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Only\u003c\/td\u003e\n\u003ctd\u003e65-2494RK   *65-2510RK \u003c\/td\u003e\n\u003ctd\u003e65-2495RK\u003c\/td\u003e\n\u003ctd\u003e65-2496RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e61-0198RK-02\u003cbr\u003e61-0198RK-03\u003cbr\u003e61-0198RK-05\u003cbr\u003e61-0198RK-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd\u003e0 – 5000ppm\u003cbr\u003e0 – 5.0%Vol.\u003cbr\u003e0 – 50%Vol.\u003cbr\u003e0 – 100%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd\u003e20 seconds or less\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e35 seconds or less\u003c\/td\u003e\n\u003ctd\u003e60 seconds or less\u003c\/td\u003e\n\u003ctd\u003e30 seconds or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e+\/- 5% of full scale (0.5% volume for oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e2 years withnormal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e5 years plus with\u003cbr\u003enormal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eIndoor or outdoor, Class I, Div. 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-4°F to 122°F\u003cbr\u003e-20°C to 50°C\u003c\/td\u003e\n\u003ctd\u003e14°F to 104°F\u003cbr\u003e-10°C to 40°C\u003c\/td\u003e\n\u003ctd\u003e-40°F to 122°F\u003cbr\u003e-40°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e0 – 99% RH non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCast aluminum, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"17\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\" alt=\"S2 toxic sensor\" nitro-lazy-empty=\"\" nitro-lazy-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rki-official-6045734ccb8f2dd7.png?v=1794161249\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e\u003ch3\u003eToxic Direct Connect Sensor Ordering Information\u003c\/h3\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number With J-Box\u003c\/td\u003e\n\u003ctd\u003ePart Number Without J-box\u003c\/td\u003e\n\u003ctd\u003eGas\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eSensor type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-NH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-NH3\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)*\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-75\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-75\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-1\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-1\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-2\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-2\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 200 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-NH3-5\u003c\/td\u003e\n\u003ctd\u003e65-2302-NH3-5\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 500 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-AsH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-AsH3\u003c\/td\u003e\n\u003ctd\u003eArsine (AsH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CL2-3\u003c\/td\u003e\n\u003ctd\u003e65-2302-CL2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CL2-10\u003c\/td\u003e\n\u003ctd\u003e65-2302-CL2-10\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 10.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-1\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-1\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-3\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2303-CLO2-5\u003c\/td\u003e\n\u003ctd\u003e65-2302-CLO2-5\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 5.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-HCN\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-HCN\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-PH3\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-PH3\u003c\/td\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2301RK-SO2\u003c\/td\u003e\n\u003ctd\u003e65-2300RK-SO2\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide (SO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003e* Sensor being phased out, use CT-7 type when possible.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"3\"\u003e\u003ch3\u003eDirect Connect Wiring Matrix\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eSensor\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eNumber of Wires to Controller\u003c\/td\u003e\n\u003ctd\u003eMaximum Distance to Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e18 AWG wire min.\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL \/ CO2 \/ IR\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2S\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e500 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdd J-Box — SKU: 61-1001RK\u003c\/li\u003e\n\u003cli\u003eSensor Only — SKU: NC-6205-01\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"Add J-Box","offer_id":39515565752355,"sku":"61-1001RK","price":1042.5,"currency_code":"USD","in_stock":true},{"title":"Sensor Only","offer_id":39515565785123,"sku":"NC-6205-01","price":842.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Direct-Connect-Sensors-by-RKI-Instruments-russmillsafety.com_677400eb-7875-4da9-9853-1ff69ccd42e5.png?v=1637682164"},{"product_id":"s2-series-gas-sensor-transmitter-by-rki-instruments","title":"S2 Series – Gas Sensor\/Transmitter by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e S2 series diffusion gas sensor\/transmitters for fixed systems: highly reliable, very cost-effective detection of common gas hazards, with 4-20 mA output.\u003c\/p\u003e\n\u003cp\u003eGas options: Methane (CH4), LEL - H2 Specific, Hydrogen Sulfide (H2S), Hydrocarbons (HC), H2 (0-1000 ppm), H2 (0-2000 ppm), LEL, Oxygen (O2), Carbon Monoxide (CO), CO2 (0-100% Vol.), CO2 (0-5.0% Vol.), CO2 (0-50% Vol.), CO2 (0-5000 ppm).\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable for LEL, H2-specific (LEL and ppm), oxygen, H2S, CO, CO2 and a variety of toxic gases; LEL by catalytic bead or infrared\u003c\/li\u003e\n\u003cli\u003eLEL, H2-specific, oxygen, H2S, CO2 and CO transmitters are explosion-proof with flame arrestors, approved for Class I, Div. 1, Groups B, C, D; optional non-explosion-proof version for oxygen, H2S, CO and CO2 (Class 1, Div. 2)\u003c\/li\u003e\n\u003cli\u003eToxic sensors (NH3, AsH3, Cl2, ClO2, HCN, PH3, SO2) are electrochemical plug-in types with high specificity, fast response and long life; tool-free field replacement; for Class I, Div. 2\u003c\/li\u003e\n\u003cli\u003eIndoor or outdoor use; patented water-repellent flame arrestor coating; splash guards for very wet environments\u003c\/li\u003e\n\u003cli\u003eOptional stainless steel junction box for corrosive environments\u003c\/li\u003e\n\u003cli\u003eInterfaces with RKI controllers or PLC\/DCS systems\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eLEL\u003cbr\u003eGeneral Purpose\u003c\/td\u003e\n\u003ctd\u003eLEL\u003cbr\u003eH2 Specific\u003c\/td\u003e\n\u003ctd\u003eH2 PPM\u003cbr\u003eHydrogen\u003c\/td\u003e\n\u003ctd\u003eO2\u003cbr\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003eH2S\u003cbr\u003eHydrogen Sulfide\u003c\/td\u003e\n\u003ctd\u003eCO\u003cbr\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eCH4\u003cbr\u003eMethane IR\u003c\/td\u003e\n\u003ctd\u003eHC\u003cbr\u003eHydrocarbons IR\u003c\/td\u003e\n\u003ctd\u003eCO2\u003cbr\u003eCarbon Dioxide IR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePart #\u003c\/td\u003e\n\u003ctd\u003e 65-2405RK \u003c\/td\u003e\n\u003ctd\u003e 65-2451RK \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2443-500 65-2443-1000 65-2443-2000 \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2322RK \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2331RK \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2336RK \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2394RK-CH4 \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2394RK-HC \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e 65-2396RK-02 65-2396RK-03 65-2396RK-05 65-2396RK-10 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 65-2405RK-05 \u003c\/td\u003e\n\u003ctd\u003e 65-2451RK-05 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e Catalytic \u003c\/td\u003e\n\u003ctd\u003e Metal oxide\u003cbr\u003esemiconductor \u003c\/td\u003e\n\u003ctd\u003e Galvanic cell \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e Electrochemical \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e Infrared \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e 0-100% LEL \u003c\/td\u003e\n\u003ctd\u003e 0-100% LEL (H2 Specific) \u003c\/td\u003e\n\u003ctd\u003e 0-500 ppm 0-1000 ppm 0-2000 ppm \u003c\/td\u003e\n\u003ctd\u003e 0-25% Vol. \u003c\/td\u003e\n\u003ctd\u003e 0-100 ppm \u003c\/td\u003e\n\u003ctd\u003e 0-300 ppm \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e 0-100% LEL \u003c\/td\u003e\n\u003ctd\u003e 0 – 5000 ppm 0 – 5% Vol. 0 – 50% Vol. 0 – 100% Vol. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 2% of full scale \u003c\/td\u003e\n\u003ctd\u003e 0.1% Vol. \u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e 2% of full scale \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003e(whichever is greater)\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e ± 5% of\u003cbr\u003ereading or\u003cbr\u003e± 2% LEL \u003c\/td\u003e\n\u003ctd\u003e ± 10% of full scale \u003c\/td\u003e\n\u003ctd\u003e ±0.5% O2 \u003c\/td\u003e\n\u003ctd\u003e ± 5% of\u003cbr\u003ereading\u003cbr\u003e± 2 ppm H2S \u003c\/td\u003e\n\u003ctd\u003e ± 5% of\u003cbr\u003ereading\u003cbr\u003e± 5 ppm CO \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e ± 5% of\u003cbr\u003ereading or\u003cbr\u003e± 2% of full scale \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd\u003e 30 Seconds \u003c\/td\u003e\n\u003ctd\u003e 20 Seconds \u003c\/td\u003e\n\u003ctd\u003e 45 Seconds \u003c\/td\u003e\n\u003ctd\u003e 90 Seconds \u003c\/td\u003e\n\u003ctd\u003e 60 Seconds \u003c\/td\u003e\n\u003ctd\u003e 90 Seconds \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 30 Seconds \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Draw (24VDC)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 70 mA (power wires) 25 mA (signal wires) 3 wires \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 25 mA max, 2 wires \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 60 mA (power wires) 25 mA (signal wires) 3 wires \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife\u003cbr\u003eExpectancy\u003c\/td\u003e\n\u003ctd\u003e 2 to 3 years with normal exposure to flammable gas \u003c\/td\u003e\n\u003ctd\u003e 3-5 years with normal service \u003c\/td\u003e\n\u003ctd\u003e 5 years plus with normal service \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 2-3 years with normal service \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 5 years plus with normal service \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation \u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e Indoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, and D. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e -40°F to 167°F -40°C to 75°C \u003c\/td\u003e\n\u003ctd\u003e -4°F to 104°F -20°C to 40°C \u003c\/td\u003e\n\u003ctd\u003e -4°F to 113°F -20°C to 45°C \u003c\/td\u003e\n\u003ctd\u003e -40°F to 104°F -40°C to 40°C \u003c\/td\u003e\n\u003ctd\u003e 23°F to 104°F -5°C to 40°C \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e -40°F to 122°F -40°C to 50°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e0 – 99% RH, non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J Box\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCast aluminum explosion proof, optional stainless steel J-box available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eStainless steel explosion proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"10\"\u003eControls\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eSets transmitter output to 4 mA with zero output from sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eSets transmitter output to proper level when span gas is applied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003e4 – 20 mA signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e 11 VDC to 30 VDC \u003c\/td\u003e\n\u003ctd\u003e 19 VDC to 30 VDC \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 19-30VDC (250 OHMS impedance max) \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 11 VDC to 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003e 65-2405RK UL \u003c\/td\u003e\n\u003ctd\u003e 65-2451RK UL \u003c\/td\u003e\n\u003ctd\u003e 65-2443-500\u003cbr\u003e65-2443-1000\u003cbr\u003e65-2443-2000 UL \u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003e CSA NRTL \u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003e C UL US \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e 65-2405RK-05\u003cbr\u003eCSA \u003c\/td\u003e\n\u003ctd\u003e 65-2451RK-05\u003cbr\u003eCSA \u003c\/td\u003e\n\u003ctd\u003e 65-2443-500-05\u003cbr\u003e65-2443-1000-05\u003cbr\u003e65-2443-2000-05 CSA \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"9\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e O2\u003cbr\u003eOxygen \u003c\/td\u003e\n\u003ctd\u003e H2S\u003cbr\u003eHydrogen Sulfide \u003c\/td\u003e\n\u003ctd\u003e CO\u003cbr\u003eCarbon Monoxide \u003c\/td\u003e\n\u003ctd\u003e Toxics\u003cbr\u003eSee chart below \u003c\/td\u003e\n\u003ctd\u003e CO2\u003cbr\u003eCarbon Dioxide \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart #\u003c\/td\u003e\n\u003ctd\u003e 65-2320RK \u003c\/td\u003e\n\u003ctd\u003e 65-2330RK \u003c\/td\u003e\n\u003ctd\u003e 65-2335RK \u003c\/td\u003e\n\u003ctd\u003e See chart\u003cbr\u003ebelow \u003c\/td\u003e\n\u003ctd\u003e 65-2397RK-02 65-2397RK-03 65-2397RK-05 65-2397RK-10   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd\u003e Galvanic cell \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e Electrochemical \u003c\/td\u003e\n\u003ctd\u003e Infrared \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e 0-25% Vol. \u003c\/td\u003e\n\u003ctd\u003e 0-100 ppm \u003c\/td\u003e\n\u003ctd\u003e 0-300 ppm \u003c\/td\u003e\n\u003ctd\u003e See chart\u003cbr\u003ebelow \u003c\/td\u003e\n\u003ctd\u003e 0 – 5000 ppm 0 – 5% Vol. 0 – 50% Vol. 0 – 100% Vol. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd\u003e 0.1% Vol. \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e 2% of full scale \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Accuracy   (whichever is greater) \u003c\/td\u003e\n\u003ctd\u003e ± 0.5% O2 \u003c\/td\u003e\n\u003ctd\u003e ± 5% of\u003cbr\u003ereading\u003cbr\u003e± 2 ppm H2S \u003c\/td\u003e\n\u003ctd\u003e ± 5% of\u003cbr\u003ereading\u003cbr\u003e± 5 ppm CO \u003c\/td\u003e\n\u003ctd\u003e ± 10% of\u003cbr\u003ereading or\u003cbr\u003e± 5% of full scale \u003c\/td\u003e\n\u003ctd\u003e ± 5% of\u003cbr\u003ereading or\u003cbr\u003e± 2% of full scale \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd\u003e 20 Seconds \u003c\/td\u003e\n\u003ctd\u003e 45 Seconds \u003c\/td\u003e\n\u003ctd\u003e 30 Seconds \u003c\/td\u003e\n\u003ctd\u003e 60 Seconds \u003c\/td\u003e\n\u003ctd\u003e 30 Seconds \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Draw (24VDC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e 25 mA max, 2 wires \u003c\/td\u003e\n\u003ctd\u003e 60 mA (power wires) 25 mA (signal wires) 3 wires \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd\u003e 2 years normal\u003cbr\u003eservice \u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 2 to 3 years with normal service \u003c\/td\u003e\n\u003ctd\u003e 5 years plus with\u003cbr\u003enormal service \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e Indoor Class I, Div. 2 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e -4°F to 122°F -20°C to 50°C \u003c\/td\u003e\n\u003ctd\u003e 14°F to 104°F -10°C to 40°C \u003c\/td\u003e\n\u003ctd\u003e -40°F to 122°F -40°C to 50°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e 0 – 99% RH non condensing \u003c\/td\u003e\n\u003ctd\u003e 5-95% RH \u003c\/td\u003e\n\u003ctd\u003e 0 – 99% RH\u003cbr\u003enon condensing \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eHousing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCast aluminum, explosion-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003ePlastic or aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"6\"\u003eControls\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZero\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eSets transmitter output to 4 mA with zero output from sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpan\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eSets transmitter output to 20 mA with full scale output from sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e19 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e4-20 mA signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eCompatible with the following controllers: Beacon 110, Beacon 200, Beacon 410A, and 800, also PLC and DCS systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003ch3\u003eS2 Non Explosion Proof Toxic Assemblies\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number With J-Box\u003c\/td\u003e\n\u003ctd\u003eGas\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2340RK-NH3\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)*\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-NH3-75\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-NH3-1\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-NH3-2\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 200 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-NH3-5\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 500 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2340RK-AsH3\u003c\/td\u003e\n\u003ctd\u003eArsine (AsH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-CL2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-CL2-05\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 5.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.02 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-CL2-10\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 10.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2341-CLO2-1\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2340RK-HCN\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2340RK-PH3\u003c\/td\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2340RK-SO2\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide (SO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"5\"\u003e\u003ch3\u003eS2 Wiring Matrix\u003c\/h3\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eS2 Transmitter\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eNumber of Wires to Controller\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMaximum Distance to Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e18 AWG wire\u003c\/td\u003e\n\u003ctd\u003e16 AWG wire\u003c\/td\u003e\n\u003ctd\u003e14 AWG wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL \/ IR \/ CO2\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e2500 ft.\u003c\/td\u003e\n\u003ctd\u003e5,000 ft.\u003c\/td\u003e\n\u003ctd\u003e8,000 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2500 ft.\u003c\/td\u003e\n\u003ctd\u003e5,000 ft.\u003c\/td\u003e\n\u003ctd\u003e8,000 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2S\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2500 ft.\u003c\/td\u003e\n\u003ctd\u003e5,000 ft.\u003c\/td\u003e\n\u003ctd\u003e8,000 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2500 ft.\u003c\/td\u003e\n\u003ctd\u003e5,000 ft.\u003c\/td\u003e\n\u003ctd\u003e8,000 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eToxics\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2500 ft.\u003c\/td\u003e\n\u003ctd\u003e5,000 ft.\u003c\/td\u003e\n\u003ctd\u003e8,000 ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMethane (CH4) — SKU: 65-2394RK-CH4\u003c\/li\u003e\n\u003cli\u003eLEL - H2 Specific — SKU: 65-2451RK\u003c\/li\u003e\n\u003cli\u003eHydrogen Sulfide (H2S) — SKU: 65-2331RK\u003c\/li\u003e\n\u003cli\u003eHydrocarbons (HC) — SKU: 65-2394RK-HC\u003c\/li\u003e\n\u003cli\u003eH2 (0-1000 ppm) — SKU: 65-2442RK-1000\u003c\/li\u003e\n\u003cli\u003eH2 (0-2000 ppm) — SKU: 65-2442RK-2000\u003c\/li\u003e\n\u003cli\u003eLEL — SKU: 65-2405RK\u003c\/li\u003e\n\u003cli\u003eOxygen (O2) — SKU: 65-2322RK\u003c\/li\u003e\n\u003cli\u003eCarbon Monoxide (CO) — SKU: 65-2336RK\u003c\/li\u003e\n\u003cli\u003eCO2 (0-100% Vol.) — SKU: 65-2396RK-10\u003c\/li\u003e\n\u003cli\u003eCO2 (0-5.0% Vol.) — SKU: 65-2396RK-03\u003c\/li\u003e\n\u003cli\u003eCO2 (0-50% Vol.) — SKU: 65-2396RK-05\u003c\/li\u003e\n\u003cli\u003eCO2 (0-5000 ppm) — SKU: 65-2396RK-02\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"Methane (CH4)","offer_id":39515586822179,"sku":"65-2394RK-CH4","price":2095.5,"currency_code":"USD","in_stock":true},{"title":"LEL - H2 Specific","offer_id":39515586658339,"sku":"65-2451RK","price":1453.15,"currency_code":"USD","in_stock":true},{"title":"Hydrogen Sulfide (H2S)","offer_id":39515586756643,"sku":"65-2331RK","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"Hydrocarbons (HC)","offer_id":39515586854947,"sku":"65-2394RK-HC","price":2095.5,"currency_code":"USD","in_stock":true},{"title":"H2 (0-1000 ppm)","offer_id":39515586691107,"sku":"65-2442RK-1000","price":1674.3,"currency_code":"USD","in_stock":true},{"title":"H2 (0-2000 ppm)","offer_id":39515590426659,"sku":"65-2442RK-2000","price":1674.3,"currency_code":"USD","in_stock":true},{"title":"LEL","offer_id":39515586625571,"sku":"65-2405RK","price":1210.95,"currency_code":"USD","in_stock":true},{"title":"Oxygen (O2)","offer_id":39515586723875,"sku":"65-2322RK","price":1368.9,"currency_code":"USD","in_stock":true},{"title":"Carbon Monoxide (CO)","offer_id":39515586789411,"sku":"65-2336RK","price":1474.2,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-100% Vol.)","offer_id":39515586887715,"sku":"65-2396RK-10","price":2095.5,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-5.0% Vol.)","offer_id":39515587608611,"sku":"65-2396RK-03","price":2095.5,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-50% Vol.)","offer_id":39515587641379,"sku":"65-2396RK-05","price":2095.5,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-5000 ppm)","offer_id":39515587674147,"sku":"65-2396RK-02","price":2095.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/S2-Series-Gas-Sensor_Transmitter-russmillsafety.com.png?v=1637684958"},{"product_id":"m2a-series-by-rki-instruments","title":"M2A Series by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e M2A series stand-alone explosion-proof transmitter: operates as an independent monitor or as part of an integrated system, connecting by analog or digital signal to virtually any controller, PLC or DCS.\u003c\/p\u003e\n\u003cp\u003eGas options: LEL - H2 Specific, Hydrogen Sulfide (H2S), Hydrocarbons (HC), LEL, Oxygen (O2), Carbon Monoxide (CO), CH4 (0-100% Vol.), CH4 (0-100%  LEL), CO2 (0-5.0% Vol.), CO2 (0-50% Vol.), CO2 (0-100% Vol.), CO2 (0-5000 ppm).\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperates with or without a controller; direct digital readout on OLED cold-temperature display\u003c\/li\u003e\n\u003cli\u003eGases: LEL, O2, H2S, CO, CO2 and 100% Vol CH4; toxics NH3, AsH3, Cl2, ClO2, HCN, PH3 and SO2; infrared sensor for combustibles and CO2\u003c\/li\u003e\n\u003cli\u003e4-20 mA and digital Modbus outputs standard\u003c\/li\u003e\n\u003cli\u003e2 fully programmable alarm relays plus fail relay\u003c\/li\u003e\n\u003cli\u003eNon-intrusive calibration via magnetic wand; housing need not be opened, so no need to declassify the area; one-person field calibration\u003c\/li\u003e\n\u003cli\u003eAutomatic zero drift correction for more stable readings\u003c\/li\u003e\n\u003cli\u003eExplosion-proof construction; patented water-repellent sensor cover\u003c\/li\u003e\n\u003cli\u003eUser-friendly push buttons and OLED menus\u003c\/li\u003e\n\u003cli\u003eLong-life sensors (2+ years typical)\u003c\/li\u003e\n\u003cli\u003eSensor construction rated Class I, Div. 1, Groups B, C, D for flammables, CO, H2S, O2 and CO2; Class I, Div. 2 for other toxics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCombustibles\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e LEL\u003cbr\u003eH2 Specific \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e O2\u003cbr\u003eOxygen \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e H2S\u003cbr\u003eHydrogen Sulfide \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e CO\u003cbr\u003eCarbon Monoxide \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e CH4\u003cbr\u003eMethane \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e HC\u003cbr\u003eHydrocarbons \u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003e CO2\u003cbr\u003eCarbon Dioxide \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL\u003c\/td\u003e\n\u003ctd\u003ePPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003ePart#\u003c\/td\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003ctd\u003e65-2640RK\u003c\/td\u003e\n\u003ctd\u003e65-2647RK\u003c\/td\u003e\n\u003ctd\u003e65-2641RK\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2643RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2645RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2646RK-05\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2649RK-CH4   65-2658RK-CH4 \u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e65-2649RK-HC\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"2\"\u003e65-2660RK-02   65-2660RK-03 65-2660RK-05 65-2660RK-10 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCSA\u003c\/td\u003e\n\u003ctd\u003e65-2640RK-05\u003c\/td\u003e\n\u003ctd\u003e65-2647RK-05\u003c\/td\u003e\n\u003ctd\u003e65-2641RK-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eSensors\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eCatalytic\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" colspan=\"3\"\u003eMeasuring Ranges\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 100% LEL\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 9000\u003cbr\u003eppmCH4\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 100%\u003cbr\u003eLEL\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 25.0% Vol.\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 300 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 100% LEL   0 – 100% Vol. \u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0 – 100% LEL\u003c\/td\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003e0 – 5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-03   -05 \u003c\/td\u003e\n\u003ctd\u003e0 – 5% Vol.   0 – 50% Vol. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0 – 100% Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1% LEL\u003c\/td\u003e\n\u003ctd\u003e20 ppm\u003c\/td\u003e\n\u003ctd\u003e1% LEL\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 ppm\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1% LEL \/ 1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 ppm \/ 0.01% Vol \/ 0.1% Vol. \/ 1% Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2% of full scale\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eMax Current Draw (24VDC)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e160 mA with alarm 1 and alarm 2 active and all relays energized\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e125 mA with alarm 1 and alarm 2   active and all relays energized \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e160 mA with alarm 1 and alarm 2   active and all relays energized \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e35 Seconds or less\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003cbr\u003eor less\u003c\/td\u003e\n\u003ctd\u003e60 Seconds\u003cbr\u003eor less\u003c\/td\u003e\n\u003ctd\u003e90 Seconds\u003cbr\u003eor less\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e30 Seconds or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd\u003e3 to 5 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e5 years plus with normal service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAccuracy\u003cbr\u003e(which ever is greater)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e± 5% of reading or ± 2% of full scale\u003c\/td\u003e\n\u003ctd\u003e± 0.5% Vol. O2\u003c\/td\u003e\n\u003ctd\u003e± 5% of\u003cbr\u003ereading or\u003cbr\u003e± 2 ppm H2S\u003c\/td\u003e\n\u003ctd\u003e± 5% of\u003cbr\u003ereading or\u003cbr\u003e± 5 ppm CO\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e± 5% of reading or ± 2 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eWeather Resistant\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003ePatented water repellent sensor coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"13\"\u003eAlarms\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAlarm Settings\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eTwo fully programmable alarm set points, increasing \/ decreasing, latching \/\u003cbr\u003eself-resetting, on delays, off delays, normally energized or de-energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAlarm Indication\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eVisual LEDs. Alarm 1, Amber; Alarm 2, Red; Fail, Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRelays\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003e5 amp form ‘C’ contacts for alarm 1, alarm 2, and fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"13\"\u003ePhysical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eHeight: 8.5” (215 mm), Width: 5.2” (132 mm), Depth: 4.5” (114 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eAlphanumeric OLED display. 8 characters per line;\u003cbr\u003e2 lines for gas concentration readout, plus user-friendly calibration and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eExplosion proof for Class I, Div 1, Groups B, C, D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eNEMA 4X, explosion proof, watertight, cast aluminum with o-ring seal and epoxy powder coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eControls\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eMagnet used for calibration functions. Calibrates without opening the housing.\u003cbr\u003eInternal push-button controls also available for calibration and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"13\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e-40°F to 167°F   -40°C to 75°C \u003c\/td\u003e\n\u003ctd\u003e-4°F to 113°F   -20°C to 45°C \u003c\/td\u003e\n\u003ctd\u003e-40°F to 104°F   -40°C to 40°C \u003c\/td\u003e\n\u003ctd\u003e23°F to 104°F   -5°C to 40°C \u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e-40°F to 122°F   -40°C to 50°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003e5 – 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eIndoor or outdoor. Explosion proof for Class I, Div. 1, Groups B, C, D.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003e10 VDC – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"13\"\u003eOutputs\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eAnalog\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eLinear 4-20 mA signal, into 1000 ohms impedance max (24DC), 0 – 500 ohms max (12VDC) corresponding to 0 – full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eDigital\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eModbus RTU output standard, fully configurable, 2-wire RS-485, 1200 to 19.2k baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003eApprovals\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e65-2640RK\u003cbr\u003eUL\u003c\/td\u003e\n\u003ctd\u003e65-2641RK   UL \u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"3\"\u003eC CSA US\u003c\/td\u003e\n\u003ctd rowspan=\"2\" colspan=\"4\"\u003eC UL US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e65-2640RK-05\u003cbr\u003eC CSA US\u003c\/td\u003e\n\u003ctd\u003e65-2641RK-05\u003cbr\u003eC CSA US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eBeacon 110, Beacon 200, Beacon 410A, Beacon 800 as well as most DCS \/ PLC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"3\"\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eOne year material and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eO2\u003cbr\u003eOxygen\u003c\/td\u003e\n\u003ctd\u003eH2S\u003cbr\u003eHydrogen Sulfide\u003c\/td\u003e\n\u003ctd\u003eCO\u003cbr\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003eToxics See Chart Below\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eCO2\u003cbr\u003eCarbon Dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart#\u003c\/td\u003e\n\u003ctd\u003e65-2666RK   *65-2644RK \u003c\/td\u003e\n\u003ctd\u003e65-2662RK\u003c\/td\u003e\n\u003ctd\u003e65-2663RK\u003c\/td\u003e\n\u003ctd\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e65-2661RK-02   65-2661RK-03 65-2661RK-05 65-2661RK-10 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eGalvanic cell\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eElectrochemical\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eInfrared\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eMeasuring Ranges\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0-25% Vol.\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0-100 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003e0-300 ppm\u003c\/td\u003e\n\u003ctd rowspan=\"3\"\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd\u003e-02\u003c\/td\u003e\n\u003ctd\u003e0 – 5000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-03   -05 \u003c\/td\u003e\n\u003ctd\u003e0 – 5% Vol.   0 – 50% Vol. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-10\u003c\/td\u003e\n\u003ctd\u003e0 – 100% Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eSee Chart Below\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20 ppm \/ 0.01% Vol. \/ 0.1% Vol. \/ 1%Vol.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLower Detectable Limit (LDL)\u003c\/td\u003e\n\u003ctd\u003e0.1% Vol.\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (T-90)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e35 Seconds or less\u003c\/td\u003e\n\u003ctd\u003e60 Seconds or less\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e30 Seconds or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current Draw (24VDC)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e125 mA with alarm 1 and alarm 2 active and all relays energized\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e160 mA with alarm 1 and alarm 2 active and all relays energized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLife Expectancy\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e2 to 3 years with normal service\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e5 years plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003cbr\u003e(which ever is greater)\u003c\/td\u003e\n\u003ctd\u003e± 0.5% Vol. O2\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or\u003cbr\u003e± 2 ppm H2S\u003c\/td\u003e\n\u003ctd\u003e± 5% of reading or\u003cbr\u003e± 5 ppm CO\u003c\/td\u003e\n\u003ctd\u003e± 10% of reading or\u003cbr\u003e± 5% of full scale\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e± 5% of reading or\u003cbr\u003e± 2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"7\"\u003eAlarms\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Settings\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eTwo fully programmable alarm set points, increasing \/ decreasing, latching \/ self-resetting, on delays, off delays, normally energized or de-energized,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Indication\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eVisual LEDs. Alarm 1=Amber; Alarm 2=Red; Fail=Red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e5 Amp form ‘C’ contacts for alarm 1, alarm 2, and fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"7\"\u003ePhysical\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eHeight: 8.5” (215 mm), Width: 5.2” (132 mm), Depth: 4.5” (114 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eAlphanumeric OLED display. 8 characters per line; 2 lines for gas concentration readout, plus user-friendly calibration and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Rating\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eNon explosion proof construction, designed for Class I, Div. 2, Groups B, C, D (no certification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing J-Box\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eNEMA 4X, explosion proof, watertight, cast aluminum with o-ring seal and epoxy powder coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eMagnet used for calibration functions. Calibrates without opening the housing. Internal push-button controls also available for calibration and setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eAluminum \/ Plastic (non explosion proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"7\"\u003eOperating Environment\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-4°F to 113°F   -20°C to 45°C \u003c\/td\u003e\n\u003ctd\u003e-40°F to 104°F   -40°C to 40°C \u003c\/td\u003e\n\u003ctd\u003e23°F to 104°F   -5°C to 40°C \u003c\/td\u003e\n\u003ctd\u003e14°F to 104°F   -10°C to 40°C \u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-40°F to 122°F   -40°C to 50°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e5 – 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eIndoor or outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003e10 VDC – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"7\"\u003eOutputs\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eLinear 4-20 mA signal, into 1000 ohms impedance max (24DC), 0 – 500 ohms max (12VDC) corresponding to 0 – full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eModbus RTU output standard, fully configurable, 2-wire RS-485, 1200 to 19.2k baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControllers\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eBeacon 110, Beacon 200, Beacon 410A, Beacon 800 as well as most DCS \/ PLC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd colspan=\"6\"\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"12\"\u003e\u003c\/td\u003e\n\u003ctd\u003ePart Number With J-Box\u003c\/td\u003e\n\u003ctd\u003eGas\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670RK-NH3-75\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670-NH3-1\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670-NH3-2\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 200 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670-NH3-5\u003c\/td\u003e\n\u003ctd\u003eAmmonia (NH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 500 ppm\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2648RK-AsH3\u003c\/td\u003e\n\u003ctd\u003eArsine (AsH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.50 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670RK-CL2-3\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670RK-CL2-10\u003c\/td\u003e\n\u003ctd\u003eChlorine (Cl2)\u003c\/td\u003e\n\u003ctd\u003e0 – 10.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2670RK-CLO2\u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide (ClO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eCT-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2648RK-HCN\u003c\/td\u003e\n\u003ctd\u003eHydrogen Cyanide (HCN)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2648RK-PH3\u003c\/td\u003e\n\u003ctd\u003ePhosphine (PH3)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e65-2648RK-SO2\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide (SO2)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.00 ppm\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003ctd\u003eESM -01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003e*Partial pressure sensor for helium (He) applications: consult factory for details.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLEL - H2 Specific — SKU: 65-2641RK\u003c\/li\u003e\n\u003cli\u003eHydrogen Sulfide (H2S) — SKU: 65-2645RK-05\u003c\/li\u003e\n\u003cli\u003eHydrocarbons (HC) — SKU: 65-2649RK-HC\u003c\/li\u003e\n\u003cli\u003eLEL — SKU: 65-2640RK\u003c\/li\u003e\n\u003cli\u003eOxygen (O2) — SKU: 65-2643RK-05\u003c\/li\u003e\n\u003cli\u003eCarbon Monoxide (CO) — SKU: 65-2646RK-05\u003c\/li\u003e\n\u003cli\u003eCH4 (0-100% Vol.) — SKU: 65-2658RK-CH4-4\u003c\/li\u003e\n\u003cli\u003eCH4 (0-100%  LEL) — SKU: 65-2649RK-CH4-4\u003c\/li\u003e\n\u003cli\u003eCO2 (0-5.0% Vol.) — SKU: 65-2660RK-03\u003c\/li\u003e\n\u003cli\u003eCO2 (0-50% Vol.) — SKU: 65-2660RK-05\u003c\/li\u003e\n\u003cli\u003eCO2 (0-100% Vol.) — SKU: 65-2660RK-10\u003c\/li\u003e\n\u003cli\u003eCO2 (0-5000 ppm) — SKU: 65-2660RK-02\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"LEL - H2 Specific","offer_id":39515675394083,"sku":"65-2641RK","price":2000.7,"currency_code":"USD","in_stock":true},{"title":"Hydrogen Sulfide (H2S)","offer_id":39515675459619,"sku":"65-2645RK-05","price":2316.6,"currency_code":"USD","in_stock":true},{"title":"Hydrocarbons (HC)","offer_id":39515675557923,"sku":"65-2649RK-HC","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"LEL","offer_id":39515675361315,"sku":"65-2640RK","price":2000.7,"currency_code":"USD","in_stock":true},{"title":"Oxygen (O2)","offer_id":39515675426851,"sku":"65-2643RK-05","price":2106.0,"currency_code":"USD","in_stock":true},{"title":"Carbon Monoxide (CO)","offer_id":39515675492387,"sku":"65-2646RK-05","price":2316.6,"currency_code":"USD","in_stock":true},{"title":"CH4 (0-100% Vol.)","offer_id":39515675525155,"sku":"65-2658RK-CH4-4","price":3159.0,"currency_code":"USD","in_stock":true},{"title":"CH4 (0-100%  LEL)","offer_id":39515675590691,"sku":"65-2649RK-CH4-4","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-5.0% Vol.)","offer_id":39515675983907,"sku":"65-2660RK-03","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-50% Vol.)","offer_id":39515677163555,"sku":"65-2660RK-05","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-100% Vol.)","offer_id":39515675951139,"sku":"65-2660RK-10","price":2948.4,"currency_code":"USD","in_stock":true},{"title":"CO2 (0-5000 ppm)","offer_id":39515677196323,"sku":"65-2660RK-02","price":2948.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/M2A-Series-disp-russmillsafety.com.png?v=1637693250"},{"product_id":"t3a-gas-detector-by-by-rki-instruments","title":"T3A Gas Detector by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e T3A Series 3-wire explosion-proof gas detector transmitter: a versatile fixed detector for ambient-air hazardous gases, using electrochemical, infrared or catalytic bead sensors.\u003c\/p\u003e\n\u003cp\u003eChoose gas type and range from the options above.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eElectrochemical, infrared or catalytic bead sensors detect a variety of gases\u003c\/li\u003e\n\u003cli\u003eWired power (3-wire), 12 to 35 VDC\u003c\/li\u003e\n\u003cli\u003e4-20 mA analog and RS-485 Modbus outputs standard\u003c\/li\u003e\n\u003cli\u003eMagnetic switches allow non-intrusive calibration in the field, plus full system settings and diagnostics\u003c\/li\u003e\n\u003cli\u003eLCD display with LED backlight; 3 push-button interface (ADD, MENU, SUB)\u003c\/li\u003e\n\u003cli\u003e2 individually configurable alarms with amber and red front-panel LEDs\u003c\/li\u003e\n\u003cli\u003e2 optional fully programmable alarm relays (dry contacts)\u003c\/li\u003e\n\u003cli\u003eOperating temperature -40°C to +60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSensor options\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eGas Type\u003c\/td\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eT90\u003c\/td\u003e\n\u003ctd\u003eHazard Classification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL Catalytic\u003c\/td\u003e\n\u003ctd\u003e0 – 100% (0-5% Vol.)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 90 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCL2\u003c\/td\u003e\n\u003ctd\u003e0 – 10 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 60 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCLO2\u003c\/td\u003e\n\u003ctd\u003e0 – 1 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 120 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCO2\u003c\/td\u003e\n\u003ctd\u003e0 – 5% vol.\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2S\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH2S 2K\u003c\/td\u003e\n\u003ctd\u003e0 – 2000 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 25 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCL\u003c\/td\u003e\n\u003ctd\u003e0 – 30 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 300 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCN\u003c\/td\u003e\n\u003ctd\u003e0 – 30 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 70 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHF\u003c\/td\u003e\n\u003ctd\u003e0 – 10 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 90 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL-IR\u003c\/td\u003e\n\u003ctd\u003e0 – 100% (0-5% Vol.)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLEL-IR-HC\u003c\/td\u003e\n\u003ctd\u003e0 – 100% LEL\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNH3\u003c\/td\u003e\n\u003ctd\u003e0 – 100 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 90 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNH3 300\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 120 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNH3 A\u003c\/td\u003e\n\u003ctd\u003e0 – 1000 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 120 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNO2\u003c\/td\u003e\n\u003ctd\u003e0 – 20 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 25 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO2\u003c\/td\u003e\n\u003ctd\u003e0 – 25 Vol.\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePH3\u003c\/td\u003e\n\u003ctd\u003e0 – 5 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 30 sec.\u003c\/td\u003e\n\u003ctd\u003eClass 1, Div 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSO2\u003c\/td\u003e\n\u003ctd\u003e0 – 20 ppm\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 35 sec.\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eClass 1, Div 1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eElectrochemical, infrared, catalytic bead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eWired power (3-Wire) 12 to 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Draw\u003c\/td\u003e\n\u003ctd\u003e2 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eProtection\u003c\/td\u003e\n\u003ctd\u003ePower electromagnetic interference (EMI) filter\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e4-20 mA surge suppression\u003c\/p\u003e\n\u003cp\u003eRS-485 surge suppression\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDisplay Screen\u003c\/td\u003e\n\u003ctd\u003e102×64 Resolution graphical LCD screen transflective (sunlight readable) with white LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e3 Push-buttons (MENU, ADD and SUB)\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e3 Magnetic non-intrusive switches for calibration\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCustomizable Settings\u003c\/td\u003e\n\u003ctd\u003e2 Individual-configurable alarm LED\/relay set-points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +60°C (-40°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOutput (digital)\u003c\/td\u003e\n\u003ctd\u003eRS-485 modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWired (Analog) Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (3-Wire)\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eFault terminal, wet relay contact. Has it’s own power.\u003c\/p\u003e\n\u003cp\u003eOptional 2 dry-contact relays with replaceable 4 amp fuses.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 in, L x 6 in. W x 7 in. H (8 in. W x 17 in. H Max. dimensions with attachments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTotal Weight\u003c\/td\u003e\n\u003ctd\u003e6 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRemote Sensor Kit\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e(Optional Additional Feature)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eRemote sensor kit with enclosure (5 pin)\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e• Electrochemical sensor max. length: 250 feet\u003c\/p\u003e\n\u003cp\u003e• Infrared sensor max. length: 40 feet\u003c\/p\u003e\n\u003cp\u003e• Catalytic bead sensor max. length: 15 feet\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHazardous Location\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eApprovals\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003eMain Enclosure\u003c\/td\u003e\n\u003ctd\u003eCertified explosion \/ flame proof CQPSUS\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eClass I, Division 1 \u0026amp; 2, Groups B, C \u0026amp; D\u003c\/p\u003e\n\u003cp\u003eNema 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)\u003c\/p\u003e\n\u003cp\u003eTemp.= -20°C to +60°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Housing\u003c\/td\u003e\n\u003ctd\u003eCertified explosion \/ flame proof CQPSUS\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eClass I, Division 1 \u0026amp; 2, Groups B, C \u0026amp; D\u003c\/p\u003e\n\u003cp\u003eTemp.= -40°C to +60°C\u003c\/p\u003e\n\u003cp\u003eNote: Certification only applies to some gases. Toxic gases not certified for Div. 1 locations are suitable for Div. 2 applications but have no third party approval.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eControllers\u003c\/td\u003e\n\u003ctd\u003eControllers compatible with all RKI Beacon controllers, as well as most DCS \/ PLC systems: Beacon 110, Beacon 200, Beacon 410A, Beacon 800, and MC-6400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-Year warranty for electronics and sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAmmonia (NH3) \/ 0 to 100 ppm — SKU: 66-6306-10\u003c\/li\u003e\n\u003cli\u003eAmmonia (NH3) \/ 0 to 200 ppm — SKU: 66-6306-20\u003c\/li\u003e\n\u003cli\u003eAmmonia (NH3) \/ 0 to 400 ppm — SKU: 66-6306-40\u003c\/li\u003e\n\u003cli\u003eCarbon Dioxide (CO2) \/ 0 to 5% — SKU: 66-6350-05\u003c\/li\u003e\n\u003cli\u003eCarbon Monoxide (CO) \/ 0 to 300 ppm — SKU: 66-6301-03\u003c\/li\u003e\n\u003cli\u003eChlorine (CI2) \/ 0 to 3 ppm — SKU: 66-6312-03\u003c\/li\u003e\n\u003cli\u003eChlorine (CI2) \/ 0 to 10 ppm — SKU: 66-6312-10\u003c\/li\u003e\n\u003cli\u003eChlorine (CI2) \/ 0 to 20 ppm — SKU: 66-6312-20\u003c\/li\u003e\n\u003cli\u003eChlorine Dioxide (ClO2) \/ 0 to 1 ppm — SKU: 66-6313-01\u003c\/li\u003e\n\u003cli\u003eChlorine Dioxide (ClO2) \/ 0 to 5 ppm — SKU: 66-6313-05\u003c\/li\u003e\n\u003cli\u003eHydrocarbon (CH4) - LEL catalytic \/ 0 to 100% — SKU: 66-6340-10\u003c\/li\u003e\n\u003cli\u003eHydrocarbon (CH4) - LEL IR \/ 0 to 100% — SKU: 66-6351-10\u003c\/li\u003e\n\u003cli\u003eHydrocarbon (HC) LEL - IR \/ 0 to 100% — SKU: 66-6353-10\u003c\/li\u003e\n\u003cli\u003eHydrogen Chloride (HCl) \/ 0 to 30 ppm — SKU: 66-6304-30\u003c\/li\u003e\n\u003cli\u003eHydrogen Cyanide (HCN) \/ 0 to 30 ppm — SKU: 66-6305-30\u003c\/li\u003e\n\u003cli\u003eHydrogen Fluoride (HF) \/ 0 to 10 ppm — SKU: 66-6314-10\u003c\/li\u003e\n\u003cli\u003eHydrogen Sulfide (H2S) \/ 0 to 100 ppm — SKU: 66-6303-10\u003c\/li\u003e\n\u003cli\u003eNitric Oxide (NO) \/ 0 to 100 ppm — SKU: 66-6307-10\u003c\/li\u003e\n\u003cli\u003eNitrogen Dioxide (NO2) \/ 0 to 20 ppm — SKU: 66-6308-20\u003c\/li\u003e\n\u003cli\u003eOxygen (O2) capillary \/ 0 to 25% — SKU: 66-6302-25\u003c\/li\u003e\n\u003cli\u003ePhosphine (PH3) \/ 0 to 5 ppm — SKU: 66-6315-05\u003c\/li\u003e\n\u003cli\u003eSulfur Dioxide (SO2) \/ 0 to 20 ppm — SKU: 66-6310-20\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"Ammonia (NH3) \/ 0 to 100 ppm","offer_id":39518783471651,"sku":"66-6306-10","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Ammonia (NH3) \/ 0 to 200 ppm","offer_id":39518787731491,"sku":"66-6306-20","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Ammonia (NH3) \/ 0 to 400 ppm","offer_id":39518787764259,"sku":"66-6306-40","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Carbon Dioxide (CO2) \/ 0 to 5%","offer_id":39518788190243,"sku":"66-6350-05","price":3727.65,"currency_code":"USD","in_stock":true},{"title":"Carbon Monoxide (CO) \/ 0 to 300 ppm","offer_id":39518788616227,"sku":"66-6301-03","price":2611.45,"currency_code":"USD","in_stock":true},{"title":"Chlorine (CI2) \/ 0 to 3 ppm","offer_id":39518789042211,"sku":"66-6312-03","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Chlorine (CI2) \/ 0 to 10 ppm","offer_id":39518789074979,"sku":"66-6312-10","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Chlorine (CI2) \/ 0 to 20 ppm","offer_id":39518789107747,"sku":"66-6312-20","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Chlorine Dioxide (ClO2) \/ 0 to 1 ppm","offer_id":39518789566499,"sku":"66-6313-01","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Chlorine Dioxide (ClO2) \/ 0 to 5 ppm","offer_id":39518789599267,"sku":"66-6313-05","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Hydrocarbon (CH4) - LEL catalytic \/ 0 to 100%","offer_id":39518789730339,"sku":"66-6340-10","price":2611.45,"currency_code":"USD","in_stock":true},{"title":"Hydrocarbon (CH4) - LEL IR \/ 0 to 100%","offer_id":39518789763107,"sku":"66-6351-10","price":3727.65,"currency_code":"USD","in_stock":true},{"title":"Hydrocarbon (HC) LEL - IR \/ 0 to 100%","offer_id":39518789795875,"sku":"66-6353-10","price":3727.65,"currency_code":"USD","in_stock":true},{"title":"Hydrogen Chloride (HCl) \/ 0 to 30 ppm","offer_id":39518789828643,"sku":"66-6304-30","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Hydrogen Cyanide (HCN) \/ 0 to 30 ppm","offer_id":39518789861411,"sku":"66-6305-30","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Hydrogen Fluoride (HF) \/ 0 to 10 ppm","offer_id":39518789894179,"sku":"66-6314-10","price":3727.65,"currency_code":"USD","in_stock":true},{"title":"Hydrogen Sulfide (H2S) \/ 0 to 100 ppm","offer_id":39518783832099,"sku":"66-6303-10","price":2611.45,"currency_code":"USD","in_stock":true},{"title":"Nitric Oxide (NO) \/ 0 to 100 ppm","offer_id":39518783864867,"sku":"66-6307-10","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Nitrogen Dioxide (NO2) \/ 0 to 20 ppm","offer_id":39518789926947,"sku":"66-6308-20","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Oxygen (O2) capillary \/ 0 to 25%","offer_id":39518789959715,"sku":"66-6302-25","price":2906.3,"currency_code":"USD","in_stock":true},{"title":"Phosphine (PH3) \/ 0 to 5 ppm","offer_id":39518789992483,"sku":"66-6315-05","price":4022.5,"currency_code":"USD","in_stock":true},{"title":"Sulfur Dioxide (SO2) \/ 0 to 20 ppm","offer_id":39518790025251,"sku":"66-6310-20","price":2906.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/T3A-Gas-Detector-by-RKI-Instruments-russmillsafety.com.png?v=1794189726"},{"product_id":"voc-pro-pid-gas-detector-by-rki-instruments","title":"VOC Pro – PID Gas Detector by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e VOC Pro PID gas detector: fixed 3-wire explosion-proof transmitter using a PID sensor to detect a variety of gases.\u003c\/p\u003e\n\u003cp\u003eLamp options: 10.6 eV lamp - high PPM range PID, 10.6 eV Lamp - Low PPM Range PID, 10.0 eV Lamp -  PID, 11.7 eV Lamp -  PID. Ranges: 0 to 100 ppm, 0 to 200 ppm, 0 to 500 ppm, 0 to 1000 ppm, 0 to 2000 ppm, 0 to 10 ppm, 0 to 20 ppm, 0 to 50 ppm.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePID lamp options: 10.0 eV, 11.7 eV, 10.6 eV ppb, 10.6 eV ppm\u003c\/li\u003e\n\u003cli\u003eWired power (3-wire), 12–35 VDC\u003c\/li\u003e\n\u003cli\u003eGraphical LCD with LED backlight; 3 push-buttons with magnetic non-intrusive switches for field calibration\u003c\/li\u003e\n\u003cli\u003e2 individually configurable alarms; amber and red LED indicators; 2 optional programmable dry-contact relays\u003c\/li\u003e\n\u003cli\u003eOutputs: 4–20 mA (3-wire) analog and RS-485 Modbus\u003c\/li\u003e\n\u003cli\u003eOperating temperature −40 °C to +54 °C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications (manufacturer)\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003ePID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eWired power (3-Wire) 12 to 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003ePower Draw\u003c\/td\u003e\n\u003ctd\u003e2 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eProtection\u003c\/td\u003e\n\u003ctd\u003ePower electromagnetic interference (EMI) filter   4-20 mA surge suppression RS-485 surge suppression \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDisplay Screen\u003c\/td\u003e\n\u003ctd\u003e102×64 Resolution graphical LCD screen transflective (sunlight readable) with white LED backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e3 Push-buttons (MENU, ADD and SUB)   3 Magnetic non-intrusive switches for calibration \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eCustomizable Settings\u003c\/td\u003e\n\u003ctd\u003e2 Individual-configurable alarm LED\/relay set-points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +54°C (-40°F to +130°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eOutput (digital)\u003c\/td\u003e\n\u003ctd\u003eRS-485 modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWired (Analog) Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (3-Wire)   Fault terminal Optional 2 dry-contact relays with replaceable 4 amp fuses \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eRemote Sensor Kit   (Optional Additional Feature) \u003c\/td\u003e\n\u003ctd\u003eRemote sensor kit with enclosure (5 pin)   • PID sensor max. length: 35 feet \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 in, L x 6 in. W x 7 in. H (8 in. W x 17 in. H Max. dimensions with attachments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eTotal Weight\u003c\/td\u003e\n\u003ctd\u003e6 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003eHazardous Location   Approvals \u003c\/td\u003e\n\u003ctd\u003eMain Enclosure\u003c\/td\u003e\n\u003ctd\u003eCertified explosion \/ flame proof CQPSUS   Class I, Division 1 \u0026amp; 2, Groups B, C \u0026amp; D,\u003cbr\u003eNema 3, 4, 4X, 7 (B, C, D) 9 (E, F, G) Temp.= -20°C to +60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Housing\u003c\/td\u003e\n\u003ctd\u003eCertified explosion \/ flame proof CQPSUS   Class I, Division 1 \u0026amp; 2, Groups B, C \u0026amp; D Temp.= -40°C to +60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eControllers\u003c\/td\u003e\n\u003ctd\u003eCompatible with all RKI Beacon controllers, as well as most DCS \/ PLC systems: Beacon 110, Beacon 200, Beacon 410A and Beacon 800, MC-6400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-Year warranty for electronics, and PID sensor (Two months for 11.7 eV lamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e10.6 eV lamp - high PPM range PID \/ 0 to 100 ppm — SKU: 66-6193-10\u003c\/li\u003e\n\u003cli\u003e10.6 eV lamp - high PPM range PID \/ 0 to 200 ppm — SKU: 66-6193-20\u003c\/li\u003e\n\u003cli\u003e10.6 eV lamp - high PPM range PID \/ 0 to 500 ppm — SKU: 66-6193-50\u003c\/li\u003e\n\u003cli\u003e10.6 eV lamp - high PPM range PID \/ 0 to 1000 ppm — SKU: 66-6193-1K\u003c\/li\u003e\n\u003cli\u003e10.6 eV lamp - high PPM range PID \/ 0 to 2000 ppm — SKU: 66-6193-2K\u003c\/li\u003e\n\u003cli\u003e10.6 eV Lamp - Low PPM Range PID \/ 0 to 10 ppm — SKU: 66-6192-01\u003c\/li\u003e\n\u003cli\u003e10.6 eV Lamp - Low PPM Range PID \/ 0 to 20 ppm — SKU: 66-6192-02\u003c\/li\u003e\n\u003cli\u003e10.6 eV Lamp - Low PPM Range PID \/ 0 to 50 ppm — SKU: 66-6192-05\u003c\/li\u003e\n\u003cli\u003e10.0 eV Lamp -  PID \/ 0 to 10 ppm — SKU: 66-6195-01\u003c\/li\u003e\n\u003cli\u003e10.0 eV Lamp -  PID \/ 0 to 20 ppm — SKU: 66-6195-02\u003c\/li\u003e\n\u003cli\u003e10.0 eV Lamp -  PID \/ 0 to 50 ppm — SKU: 66-6195-05\u003c\/li\u003e\n\u003cli\u003e10.0 eV Lamp -  PID \/ 0 to 100 ppm — SKU: 66-6195-10\u003c\/li\u003e\n\u003cli\u003e11.7 eV Lamp -  PID \/ 0 to 20 ppm — SKU: 66-6194-02\u003c\/li\u003e\n\u003cli\u003e11.7 eV Lamp -  PID \/ 0 to 50 ppm — SKU: 66-6194-05\u003c\/li\u003e\n\u003cli\u003e11.7 eV Lamp -  PID \/ 0 to 100 ppm — SKU: 66-6194-10\u003c\/li\u003e\n\u003cli\u003e11.7 eV Lamp -  PID \/ 0 to 500 ppm — SKU: 66-6194-50\u003c\/li\u003e\n\u003cli\u003e11.7 eV Lamp -  PID \/ 0 to 1000 ppm — SKU: 66-6194-99\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"RKI Instruments","offers":[{"title":"10.6 eV lamp - high PPM range PID \/ 0 to 100 ppm","offer_id":39522418884643,"sku":"66-6193-10","price":4717.45,"currency_code":"USD","in_stock":false},{"title":"10.6 eV lamp - high PPM range PID \/ 0 to 200 ppm","offer_id":39522419277859,"sku":"66-6193-20","price":4717.45,"currency_code":"USD","in_stock":false},{"title":"10.6 eV lamp - high PPM range PID \/ 0 to 500 ppm","offer_id":39522419310627,"sku":"66-6193-50","price":4717.45,"currency_code":"USD","in_stock":false},{"title":"10.6 eV lamp - high PPM range PID \/ 0 to 1000 ppm","offer_id":39522419343395,"sku":"66-6193-1K","price":4717.45,"currency_code":"USD","in_stock":false},{"title":"10.6 eV lamp - high PPM range PID \/ 0 to 2000 ppm","offer_id":39522419376163,"sku":"66-6193-2K","price":4717.45,"currency_code":"USD","in_stock":false},{"title":"10.6 eV Lamp - Low PPM Range PID \/ 0 to 10 ppm","offer_id":39522419638307,"sku":"66-6192-01","price":5054.4,"currency_code":"USD","in_stock":false},{"title":"10.6 eV Lamp - Low PPM Range PID \/ 0 to 20 ppm","offer_id":39522419671075,"sku":"66-6192-02","price":5054.4,"currency_code":"USD","in_stock":false},{"title":"10.6 eV Lamp - Low PPM Range PID \/ 0 to 50 ppm","offer_id":39522419703843,"sku":"66-6192-05","price":5054.4,"currency_code":"USD","in_stock":false},{"title":"10.0 eV Lamp -  PID \/ 0 to 10 ppm","offer_id":39522419867683,"sku":"66-6195-01","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"10.0 eV Lamp -  PID \/ 0 to 20 ppm","offer_id":39522419900451,"sku":"66-6195-02","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"10.0 eV Lamp -  PID \/ 0 to 50 ppm","offer_id":39522419933219,"sku":"66-6195-05","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"10.0 eV Lamp -  PID \/ 0 to 100 ppm","offer_id":39522418950179,"sku":"66-6195-10","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"11.7 eV Lamp -  PID \/ 0 to 20 ppm","offer_id":39522420129827,"sku":"66-6194-02","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"11.7 eV Lamp -  PID \/ 0 to 50 ppm","offer_id":39522420162595,"sku":"66-6194-05","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"11.7 eV Lamp -  PID \/ 0 to 100 ppm","offer_id":39522418982947,"sku":"66-6194-10","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"11.7 eV Lamp -  PID \/ 0 to 500 ppm","offer_id":39522419998755,"sku":"66-6194-50","price":5265.0,"currency_code":"USD","in_stock":false},{"title":"11.7 eV Lamp -  PID \/ 0 to 1000 ppm","offer_id":39522420031523,"sku":"66-6194-99","price":5265.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/VOC-Pro_PID-Gas-Detector-by-RKI-Instruments-russmillsafety.com.png?v=1794189726"},{"product_id":"sp-220-gas-leak-checker","title":"SP-220 Gas Leak Checker for Combustible, Toxic, Freon and Fumigation Gases","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e SP-220 gas leak checker for combustible, toxic, freon and fumigation gases, for pinpointing hard-to-find, low-concentration leaks.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOver 40 target gases; sensitivity and range change automatically with the selected gas\u003c\/li\u003e\n\u003cli\u003eType SC: hot-wire semiconductor (MOS) sensor for gases including PH3, CH4, H2, HCl, ETO, HBr and NH3\u003c\/li\u003e\n\u003cli\u003eType FUM: detects fumigation gases including methyl bromide, sulfuryl fluoride and phosphine\u003c\/li\u003e\n\u003cli\u003eResistant to silicone poisoning\u003c\/li\u003e\n\u003cli\u003eSilenceable alarms for discreet leak checking; background gas zeroing\u003c\/li\u003e\n\u003cli\u003eSnap logging (128 readings) and data logging (256 data points)\u003c\/li\u003e\n\u003cli\u003eIntegral pump, backlit LCD, molded rubber cover, built-in LED light\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart no.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72-0064-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: SP-220GLC\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":40103215235107,"sku":"SP-220GLC","price":1836.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/sp220-scaled-1.jpg?v=1692805082"},{"product_id":"gx-2009-msha-gas-monitor","title":"GX-2009 MSHA Gas Monitor","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GX-2009 MSHA four-gas monitor: simultaneous detection of CH4, O2, NO2 and CO (or CH4, O2, H2S and CO), MSHA certified for underground mines, tunnels and excavations.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompact: 2.7 in H x 3 in W x 1 in D, 4.6 oz\u003c\/li\u003e\n\u003cli\u003eDual audible alarm ports and alarm LEDs on 3 sides; vibration alarm\u003c\/li\u003e\n\u003cli\u003eIP67 water-resistant, dustproof design; impact-resistant, RFI-resistant rubber over-mold\u003c\/li\u003e\n\u003cli\u003eLarge-capacity data logging standard (up to 100 calibration records)\u003c\/li\u003e\n\u003cli\u003eAuto-calibration; calibration\/bump test lockout or reminder; STEL\/TWA; peak hold; auto-backlit LCD; clock\u003c\/li\u003e\n\u003cli\u003eTwo glow-in-the-dark, glove-friendly buttons\u003c\/li\u003e\n\u003cli\u003eNiMH battery: 20 hours operation, full charge in 3 hours\u003c\/li\u003e\n\u003cli\u003eOptional SDM-2009 single calibration station (stand-alone or networked with up to 10 units)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCH4 (% vol), O2, CO, and NO2 or H2S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize \/ weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 x 3 x 1 in; 4.6 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNiMH, 20 h run \/ 3 h charge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntrinsically safe; MSHA classified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWindows 10, 8, 7, XP, Vista\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart no.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72-0316-MSHA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-0316-MSHA\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":40621115146275,"sku":"72-0316-MSHA","price":2011.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/GX-2009-MSHA-NO2-image.jpg?v=1730408160"},{"product_id":"gx-8000-sample-draw-gas-monitor","title":"GX-8000 Sample Draw Gas Monitor","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e GX-8000 sample-draw gas monitor: real-time detection of up to 5 ranges for combustible gas (100% vol \/ 100% LEL), O2, H2S and CO, built for harsh marine and industrial applications.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStrong sample-drawing capability\u003c\/li\u003e\n\u003cli\u003eLarge simultaneous display with auto backlighting\u003c\/li\u003e\n\u003cli\u003e95 dB alarm buzzer and 3 bright LED alarm lamps\u003c\/li\u003e\n\u003cli\u003eIP67 water and dust resistant\u003c\/li\u003e\n\u003cli\u003eLithium-ion rechargeable battery; compact and lightweight\u003c\/li\u003e\n\u003cli\u003eErgonomic design with wrist strap for hands-free use\u003c\/li\u003e\n\u003cli\u003eData logging standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombustible (100% vol \/ 100% LEL), O2, H2S, CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95 dB buzzer; 3 LED lamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX Exia II CT4 (as listed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart no.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72-0327RKC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-0327RKC\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":40621117636643,"sku":"72-0327RKC","price":10786.5,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/files\/rs-catalog-white-7061367324707-1.png?v=1794104672"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/collections\/rs-all-collections-clear-88492179515.png?v=1794097270","url":"https:\/\/russmillsafety.com\/en-br\/collections\/gas-detectors.oembed","provider":"RussmillSafety.com","version":"1.0","type":"link"}