{"product_id":"beacon-110-single-channel-wall-mount-controller-by-rki-instruments","title":"Beacon 110 Single Channel Wall Mount Controller by RKI Instruments","description":"\u003cp\u003e\u003cstrong\u003eRKI Instruments\u003c\/strong\u003e Beacon 110 single-channel wall-mount controller (72-2110RK-02, small red light, no sensor): gas detection simplified, for one point of detection.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePowerful, low-cost, microprocessor-controlled fixed system controller; simple to install and operate\u003c\/li\u003e\n\u003cli\u003eAccepts RKI LEL, O2, H2S or CO direct-connect sensors, or any 4-20 mA transmitter (2 or 3 wire, 24 VDC)\u003c\/li\u003e\n\u003cli\u003eSensors mount at the housing or wire remotely; long-life sensors (2+ years typical)\u003c\/li\u003e\n\u003cli\u003eTwo programmable alarm levels; audible alarm with reset button; built-in trouble alarm with relay\u003c\/li\u003e\n\u003cli\u003e10 A form C relays directly power external alarms and horns\u003c\/li\u003e\n\u003cli\u003eBacklit digital display shows gas type and concentration; 4-20 mA output\u003c\/li\u003e\n\u003cli\u003e115\/220 VAC or 24 VDC operation\u003c\/li\u003e\n\u003cli\u003eCompact, weatherproof NEMA 4X enclosure; complies with lock-out\/tag-out standards; external reset switch\u003c\/li\u003e\n\u003cli\u003eShips with wall mounting kit\u003c\/li\u003e\n\u003cli\u003eMade in the USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eHeight: 8.5″ 216 mm\u003cbr\u003eWidth 7.0″ 178 mm\u003cbr\u003eDepth 4.3″ 109 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eWall mounting grey polycarbonate with hinged cover.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit\u003cbr\u003eConnection\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\/4″ NPT conduit hubs, 2 provided.\u003cbr\u003e1 for sensor wiring\u003cbr\u003e1 for power \u0026amp; relay wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003cbr\u003eTermination\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eScrew type terminal block 14 gauge max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Power \u003c\/td\u003e\n\u003ctd\u003eUniversal 115 VAC \u0026amp; 220 VAC, or 24 VDC nominal, battery backup option available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Controls \u003c\/td\u003e\n\u003ctd\u003e3 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eEnvironmental\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 122°F (-20°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-4°F to 158°F (-20°C to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative\u003cbr\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0 – 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003cbr\u003eRating\u003c\/td\u003e\n\u003ctd\u003eNEMA-4X enclosure, waterproof, chemical, and weather resistant.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eInputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirect Wired\u003cbr\u003eSensors\u003c\/td\u003e\n\u003ctd\u003eLEL\u003cbr\u003eOxygen\u003cbr\u003eCarbon Monoxide\u003cbr\u003eHydrogen Sulfide\u003cbr\u003eRemote amp not required for less than 500 feet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA Sensors\u003c\/td\u003e\n\u003ctd\u003eAccepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI\/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Methods\u003c\/td\u003e\n\u003ctd\u003eDiffusion and sample draw heads available.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eOutputs\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003e3 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarms and 1 trouble relay. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003ctd\u003eSignal output, 4-20 mA (maximum load impedance 500 ohms), per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003ctd\u003e24 VDC (400 mA max) output provided to operate sample drawing adapters or other accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e2 x 8 Alphanumeric display with backlighting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAudible\u003c\/td\u003e\n\u003ctd\u003eBuilt-in audible alarm, 94 dB, mounted on enclosure\u003cbr\u003eCoded output: pulsing = gas alarm, steady = fail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual\u003c\/td\u003e\n\u003ctd\u003e3 LED’s on the front cover for alarm status indication, and malfunction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ch4\u003eWarranty\u003c\/h4\u003e\u003c\/td\u003e\n\u003ctd\u003eOne year materials and workmanship\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e Partial List Of Detectable Gases\u003cbr\u003e\u003cem\u003eMany other gases or ranges available. Contact RKI for gases or ranges not listed.\u003c\/em\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e Ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) \u003c\/td\u003e\n\u003ctd\u003e0 – 75.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArsine (AsH\u003csub\u003e3\u003c\/sub\u003e )\u003c\/td\u003e\n\u003ctd\u003e0 – 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoron Trichloride (BCl\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide (CO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Monoxide (CO)\u003c\/td\u003e\n\u003ctd\u003e0 – 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 3.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide (ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Trifluoride (ClF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombustibles\u003c\/td\u003e\n\u003ctd\u003e0 -100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiborane (B\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e6\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluorine (F\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 6.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen (H\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 2000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Chloride (HCl)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Fluoride (HF)\u003c\/td\u003e\n\u003ctd\u003e0 – 9.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrogen Sulfide (H\u003csub\u003e2\u003c\/sub\u003eS)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitric Oxide (NO)\u003c\/td\u003e\n\u003ctd\u003e0 -100.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Dioxide (NO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen Trifluoride (NF\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen (O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 25.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone (O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphine (PH\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilane (SiH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfur Dioxide (SO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 – 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTEOS (Si(OC\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e5\u003c\/sub\u003e)\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003ctd\u003e0 -15\/30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003e\u003cem\u003eSpecifications subject to change without notice.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct information supplied by the manufacturer (RKI Instruments).\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct codes\u003c\/h3\u003e\n\u003cp\u003eSKU: 72-2110RK-02\u003c\/p\u003e\n","brand":"RKI Instruments","offers":[{"title":"Default Title","offer_id":39514545651747,"sku":"72-2110RK-02","price":2158.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0076\/2960\/2875\/products\/Beacon-110-russmillsafety.com.png?v=1794189727","url":"https:\/\/russmillsafety.com\/en-br\/products\/beacon-110-single-channel-wall-mount-controller-by-rki-instruments","provider":"RussmillSafety.com","version":"1.0","type":"link"}