Specifications
Physical |
|
Dimensions | Height: 10.5” 267 mm Width: 8.5” 216 mm Depth: 6.3” 158 mm |
Enclosure | Wall mounting grey polycarbonate with hinged cover |
Conduit Connection | 3/4” NPT conduit hubs, 3 provided. 2 for sensor wiring and 1 for power & relay wiring |
Wiring Termination | Screw type terminal block, 14 gauge max |
Controls
|
4 internal push buttons for setup, programming, and calibration. 1 external push button for alarm reset |
Environmental |
|
Operating Temp | -4°F to 122°F (-10°C to 50°C) |
Storage Temp | -4°F to 158°F (-20°C to 70°C) |
Relative Humidity | 0 – 100% RH |
Enclosure Rating | NEMA-4X enclosure, waterproof, chemical, and weather resistant |
Inputs |
|
Direct Wired Sensors | LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide Remote amp not required for less than 500 feet |
4-20 mA Sensors | Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. (See list of detectable gases.) Wiring distances up to 5000 feet |
Sampling Methods | Diffusion and sample draw heads available |
Outputs |
|
Relays | 7 relays – 10 amp rating (at 115 VAC), SPDT isolated contacts. 2 relays for gas alarm levels per channel, plus 2 relays for common gas alarm and 1 common relay for malfunction. Relays fully programmable for: increasing or decreasing alarm, latching or self reset, normally energized or normally de-energized, time delay for alarm on and alarm off |
4-20 mA | Signal output, 4-20 mA (into 1000 ohms impedance maximum), per channel |
24 VDC | 24 VDC (350 mA max) output provided to operate sample drawing adapters or other accessories |
Display | Alphanumeric display with backlighting. 20 characters per line; 4 lines each |
Audible | Built-in audible alarm, 94 dB, mounted on enclosure Coded output: pulsing = gas alarm, steady = fail |
Visual | 4 LED’s on the front cover for alarm status indication, pilot, and malfunction |
Optional Expansion Cards | Individual 4-20 mA (or 1 – 5 VDC) outputs Heavy duty relay card (4 each @ 30 amps) |
Power |
110-240 VAC or 24 VDC standard. Battery backup option available |
Warranty |
One year materials and workmanship |
Partial List Of Detectable Gases Many other gases or ranges available. Contact RKI for gases or ranges not listed. | |
Ammonia (NH3)
|
0 – 75.0 ppm |
Arsine (AsH3 ) | 0 – 0.20 ppm |
Boron Trichloride (BCl3) | 0 – 15.0 ppm |
Carbon Dioxide (CO2) | 0 – 1.0 % |
Carbon Monoxide (CO) | 0 – 300 ppm |
Chlorine (Cl2) | 0 – 3.0 ppm |
Chlorine Dioxide (ClO2) | 0 – 1.00 ppm |
Chlorine Trifluoride (ClF3) | 0 – 1.00 ppm |
Combustibles | 0 -100% LEL |
Diborane (B2H6) | 0 – 30.0 ppm |
Fluorine (F2) | 0 – 6.0 ppm |
Hydrogen (H2) | 0 – 2000 ppm |
Hydrogen Chloride (HCl) | 0 – 15.0 ppm |
Hydrogen Fluoride (HF) | 0 – 9.0 ppm |
Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
Nitric Oxide (NO) | 0 -100.0 ppm |
Nitrogen Dioxide (NO2) | 0 – 15.0 ppm |
Nitrogen Trifluoride (NF3) | 0 – 30.0 ppm |
Oxygen (O2) | 0 – 25.0 % |
Ozone (O3) | 0 – 1.0 ppm |
Phosphine (PH3) | 0 – 1.0 ppm |
Silane (SiH4) | 0 – 15.0 ppm |
Sulfur Dioxide (SO2) | 0 – 30.0 ppm |
TEOS (Si(OC2H5)4) | 0 -15/30 ppm |
Specifications subject to change without notice. Made in the USA