Key benefits
- Simultaneously displays gas type, readings and status for 4 channels on an OLED display
- Monitors any combination of direct-connect LEL, O2, CO2 and toxic sensors, plus any 4-20 mA transmitter (2 or 3 wire)
- Up to 3 configurable alarm points and up to 3 alarm relays per channel; built-in trouble alarm with relay
- Silenceable audible alarm; alarm reset switch
- 4-20 mA output per channel; Modbus digital output standard
- Min-Max feature retains high and low peaks
- 115/220 VAC or external 24 VDC; optional battery backup and high-visibility strobe
- All features built in: no add-on cards needed
- RFI/EMI resistant; weather and corrosion resistant NEMA 4X enclosure
- Made in the USA
Specifications
Physical |
|
| Dimensions | Height: 12.5” Width 11” Depth 6.4” |
| Enclosure | NEMA 4X non-metallic for indoor and outdoor locations |
| Conduit Connection | 3/4” NPT conduit hubs, 4 provided, for sensor, power, & relay wiring |
| Wiring Termination | Screw type terminal block, 14 gauge max |
| Power | 115 VAC & 220 VAC, or 24 VDC nominal, battery backup option available |
| Controls | Display PCB Control Switches:
|
Environmental |
|
| Operating Temp | -4°F to 122°F (-20°C to 50°C) |
| Storage Temp | -4°F to 158°F (-20°C to 70°C) |
| Relative Humidity | 0 – 95% RH (non-condensing) |
| Enclosure Rating | NEMA-4X enclosure, chemical and weather resistant |
Inputs |
|
| Direct Wired Sensors | LEL, Oxygen, Carbon Monoxide, Hydrogen Sulfide, and Carbon Dioxide. Remote amp not required for less than 500 feet |
| 4-20 mA Sensors | Accepts any 4-20 mA transmitter (24 VDC, 2 or 3 wire). A wide variety of RKI/Riken sensors are available with 4-20 mA signals. Wiring distances up to 8,000 feet |
| Sampling Methods | Diffusion and sample draw heads available |
Outputs |
|
| Relays | Two flexible, programmable Form-C (C, NO, NC) relays per channel, plus five common relays (Fail, Alarm-1, Alarm-2, Alarm-3, Alarm-Any). Common relays may optionally be assigned to function as additional channel alarm relays, providing for up to three alarm relays per channel. 10A contact rating. |
| 4-20 mA | Signal output, 4-20 mA (maximum load impedance 500 ohms), per channel |
| RS-485 | Modbus format RS-485 serial output of all channel data, including gas reading and alarm status. |
| Display | Four line OLED display |
| Audible | Built-in audible alarm, 94 dB, mounted on enclosure Coded output: pulsing = gas alarm, steady = fail |
| Visual | 1. Alarm LEDs (on Display PCB)
|
Warranty |
One year materials and workmanship |
| Partial List Of Detectable Gases Many other gases or ranges available. Contact RKI for gases or ranges not listed. | |
| Ammonia (NH3) | 0 – 75.0 ppm |
| Arsine (AsH3 ) | 0 – 0.20 ppm |
| Boron Trichloride (BCl3) | 0 – 15.0 ppm |
| Carbon Dioxide (CO2) | 0 – 1.0 % |
| Carbon Monoxide (CO) | 0 – 300 ppm |
| Chlorine (Cl2) | 0 – 3.0 ppm |
| Chlorine Dioxide (ClO2) | 0 – 1.00 ppm |
| Chlorine Trifluoride (ClF3) | 0 – 1.00 ppm |
| Combustibles | 0 -100% LEL |
| Diborane (B2H6) | 0 – 30.0 ppm |
| Fluorine (F2) | 0 – 6.0 ppm |
| Hydrogen (H2) | 0 – 2000 ppm |
| Hydrogen Chloride (HCl) | 0 – 15.0 ppm |
| Hydrogen Fluoride (HF) | 0 – 9.0 ppm |
| Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
| Nitric Oxide (NO) | 0 -100.0 ppm |
| Nitrogen Dioxide (NO2) | 0 – 15.0 ppm |
| Nitrogen Trifluoride (NF3) | 0 – 30.0 ppm |
| Oxygen (O2) | 0 – 25.0 % |
| Ozone (O3) | 0 – 1.0 ppm |
| Phosphine (PH3) | 0 – 1.0 ppm |
| Silane (SiH4) | 0 – 15.0 ppm |
| Sulfur Dioxide (SO2) | 0 – 30.0 ppm |
| TEOS (Si(OC2H5)4) | 0 -15/30 ppm |
Specifications subject to change without notice.
Product information supplied by the manufacturer (RKI Instruments).
Product codes
SKU: 72-2104A
Couldn't load pickup availability
Discuss your requirements with Russmill Safety: sales@russmillsafety.com.
Selection & specifications
Selection & specifications
Review the product description, available variants and manufacturer’s specifications before ordering. PPE must be selected for the hazards and requirements of your workplace.
Shipping & returns
Shipping & returns
Review our Shipping Policy and Refund Policy for current terms.
Care & product support
Care & product support
Follow the manufacturer’s care, inspection and replacement instructions. Need clarification? Contact customerservice@russmillsafety.com with the product name or SKU.
Available payment methods are displayed at checkout. Review your order and delivery details before completing payment.
Quick order list
Match equipment to your workplace hazards and the manufacturer’s published specifications. Check sizing, compatible components and intended use before ordering.
Read our Shipping Policy and Refund Policy. Contact our team about product and order requirements.
Send product names or SKUs, quantities, sizes and your destination to sales@russmillsafety.com to discuss your requirements.