Specifications
Explosion Proof Class I, Div. 2 , Groups B, C, D |
|||||||||
LEL General Purpose |
LEL H2 Specific |
O2 Oxygen |
H2S Hydrogen Sulfide |
CO Carbon Monoxide |
CH4 Methane IR |
HC Hydrocarbons IR |
CO2 Carbon Dioxide IR |
||
Sensor With J-Box |
61-1000RK (UL) | 61-1001RK (UL) | 65-2515RK | 65-2427RK-05 | 65-2437RK-05 | 61-1003RK-CH4 61-1006RK-CH4 |
61-1003RK-HC | 61-1004RK-02 61-1004RK-03 61-1004RK-05 61-1004RK-10 |
|
61-1000RK-05 (CSA) | 61-1001RK-05 (CSA) | ||||||||
Sensors | Catalytic | Galvanic cell | Electrochemical | Infrared | |||||
Sensor Only |
61-0140RK (UL) 61-0140RK-05 (CSA) |
LEL H2 – NC-6205-01 (UL) NC-6205-05 (CSA) |
65-2514RK | 65-2428 | 65-2438 | 61-0190RK-CH4 61-0192RK-CH4 |
61-0190RK-HC | 61-0191RK-02 61-0191RK-03 61-0191RK-05 61-0191RK-10 |
|
Measuring Range | 0-100% LEL | 0-25% Vol. | 0-100 ppm | 0-300 ppm | 0-100% LEL 0-100% Vol. |
0-100% LEL | -02 -03 -05 -10 |
0 – 5000ppm 0 – 5.0%Vol. 0 – 50%Vol. 0 – 100%Vol. |
|
Lower Detectable Limit (LDL) | 2% of full scale | 0.1% Vol. | 2% of full scale | ||||||
Response Time (T-90) |
LEL – 30 Seconds | LEL H2 – 20 Seconds | 90 Seconds | 60 Seconds | 90 Seconds | 30 Seconds | 30 Seconds | 30 Seconds | |
Accuracy | +/- 5% of full scale (0.5% volume for oxygen) | ||||||||
Life
Expectancy |
2 to 3 years with normal service | 3 to 5 years with normal service | 2 to 3 years with normal service | 5 years plus with normal service | |||||
Operating Environment | |||||||||
Location | Indoor or outdoor. Explosion proof for Class I, Groups B, C, and D atmospheres. | ||||||||
Temperature | -40°F to 167°F -40°C to 75°C |
-4°F to 113°F -20°C to 45°C |
-40°F to 104°F -40°C to 40°C |
23°F to 104°F -5°C to 40°C |
-40°F to 122°F -40°C to 50°C |
||||
Humidity | 0 – 99% RH non condensing | ||||||||
Housing | |||||||||
Housing J-Box | Cast aluminum, explosion-proof. Optional stainless steel J-box available. | ||||||||
Sensor | Stainless steel, explosion-proof | ||||||||
Approvals | 61-1000RK UL | 61-1001RK UL | CSA NRTL | C UL US | |||||
61-1000RK-05 CSA | 61-1001RK-05 CSA | ||||||||
Controllers | Compatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A | ||||||||
Warranty | One year materials and workmanship |
Toxic Gas Transmitters Class I, Div. 2 |
|||||
O2 Oxygen |
H2S Hydrogen Sulfide |
CO Carbon Monoxide |
Toxics | CO2 Carbon Dioxide |
|
Sensor With J-Box | 65-2497RK *65-2502RK |
65-2498RK | 65-2499RK | See Chart Below | 61-1007RK-02 61-1007RK-03 61-1007RK-05 61-1007RK-10 |
Sensors | Galvanic cell | Electrochemical | Infrared | ||
Sensor Only | 65-2494RK
*65-2510RK |
65-2495RK | 65-2496RK | See Chart Below | 61-0198RK-02 61-0198RK-03 61-0198RK-05 61-0198RK-10 |
Measuring Range | 0-25% Vol. | 0-100 ppm | 0-300 ppm | 0 – 5000ppm 0 – 5.0%Vol. 0 – 50%Vol. 0 – 100%Vol. |
|
Lower Detectable Limit (LDL) | 0.1% Vol. | 2% of full scale | |||
Response Time (T-90) | 20 seconds or less | 35 seconds or less | 60 seconds or less | 30 seconds or less | |
Accuracy | +/- 5% of full scale (0.5% volume for oxygen) | ||||
Life Expectancy | 2 years withnormal service | 2 to 3 years with normal service | 5 years plus with normal service |
||
Operating Environment | |||||
Location | Indoor or outdoor, Class I, Div. 2 | ||||
Temperature | -4°F to 122°F -20°C to 50°C |
14°F to 104°F -10°C to 40°C |
-40°F to 122°F -40°C to 50°C |
||
Humidity | 0 – 99% RH non condensing | ||||
Housing | |||||
Housing J-Box | Cast aluminum, explosion-proof | ||||
Sensor | Aluminum | ||||
Controllers | Compatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410A | ||||
Warranty | One year materials and workmanship |
Toxic Direct Connect Sensor Ordering Information |
||||||
Part Number With J-Box | Part Number Without J-box | Gas | Range | Resolution | Sensor type | |
65-2301RK-NH3 | 65-2300RK-NH3 | Ammonia (NH3)* | 0 – 75.0 ppm | 0.1 ppm | ESM -01 | |
65-2303-NH3-75 | 65-2302-NH3-75 | Ammonia (NH3) | 0 – 75.0 ppm | 0.1 ppm | CT-7 | |
65-2303-NH3-1 | 65-2302-NH3-1 | Ammonia (NH3) | 0 – 100 ppm | 1 ppm | CT-7 | |
65-2303-NH3-2 | 65-2302-NH3-2 | Ammonia (NH3) | 0 – 200 ppm | 1 ppm | CT-7 | |
65-2303-NH3-5 | 65-2302-NH3-5 | Ammonia (NH3) | 0 – 500 ppm | 1 ppm | CT-7 | |
65-2301RK-AsH3 | 65-2300RK-AsH3 | Arsine (AsH3) | 0 – 1.50 ppm | 0.01 ppm | ESM -01 | |
65-2303-CL2-3 | 65-2302-CL2-3 | Chlorine (Cl2) | 0 – 3.00 ppm | 0.01 ppm | CT-7 | |
65-2303-CL2-10 | 65-2302-CL2-10 | Chlorine (Cl2) | 0 – 10.0 ppm | 0.1 ppm | CT-7 | |
65-2303-CLO2-1 | 65-2302-CLO2-1 | Chlorine Dioxide (ClO2) | 0 – 1.00 ppm | 0.01 ppm | CT-7 | |
65-2303-CLO2-3 | 65-2302-CLO2-3 | Chlorine Dioxide (ClO2) | 0 – 3.00 ppm | 0.01 ppm | CT-7 | |
65-2303-CLO2-5 | 65-2302-CLO2-5 | Chlorine Dioxide (ClO2) | 0 – 5.00 ppm | 0.01 ppm | CT-7 | |
65-2301RK-HCN | 65-2300RK-HCN | Hydrogen Cyanide (HCN) | 0 – 15.0 ppm | 0.1 ppm | ESM -01 | |
65-2301RK-PH3 | 65-2300RK-PH3 | Phosphine (PH3) | 0 – 1.00 ppm | 0.01 ppm | ESM -01 | |
65-2301RK-SO2 | 65-2300RK-SO2 | Sulfur Dioxide (SO2) | 0 – 6.00 ppm | 0.01 ppm | ESM -01 | |
* Sensor being phased out, use CT-7 type when possible. |
Direct Connect Wiring Matrix |
||
Sensor | Number of Wires to Controller | Maximum Distance to Controller |
18 AWG wire min. | ||
LEL / CO2 / IR | 4 | 500 ft. |
Oxygen | 2 | 500 ft. |
H2S | 2 | 500 ft. |
CO | 2 | 500 ft. |
Toxics | 2 | 500 ft. |
Specifications subject to change without notice.
Made in the USA
Availability: Manufacturer Sourced. Usually available/ships in 3-7 Days.